Your browser doesn't support javascript.
loading
Reconstruction Algorithm-Based CT Imaging for the Diagnosis of Hepatic Ascites.
Zhang, Huitao; Lv, Wenhao; Diao, Haofeng; Shang, Li.
Afiliación
  • Zhang H; Department of Gastroenterology, The No.4 People's Hospital of Hengshui City, Hengshui 053000, China.
  • Lv W; Department of Gastroenterology, The No.4 People's Hospital of Hengshui City, Hengshui 053000, China.
  • Diao H; Department of Spine Surgery, The No.4 People's Hospital of Hengshui City, Hengshui 053000, China.
  • Shang L; Department of Gastroenterology, The No.4 People's Hospital of Hengshui City, Hengshui 053000, China.
Comput Math Methods Med ; 2022: 1809186, 2022.
Article en En | MEDLINE | ID: mdl-35572834
ABSTRACT
The study was aimed at exploring the diagnostic value of artificial intelligence reconstruction algorithm combined with CT image parameters on hepatic ascites, expected to provide a reference for the etiological evaluation of clinical abdominal effusion. Specifically, the adaptive iterative hard threshold (AIHT) algorithm for CT image reconstruction was proposed. Then, 100 patients with peritoneal effusion were selected as the research subjects. After 8 cases were excluded, the remaining was divided into 50 cases of the S1 group (hepatic ascites) and 42 cases of the D0 group (cancerous peritoneal effusion). Gemstone energy spectrum CT scanning was performed on all patients, and CT image parameters of the two groups were compared. It was found that CT value of mixed energy, CT value of 60-100 KeV single energy, concentration value of water (calcium), concentration value of water (iodine), and slope of energy spectrum curve in the S1 group were significantly lower than those in the D0 group (P < 0.05). The effective atomic number in the S1 group was significantly higher than that in the D0 group (P < 0.05). Of the 50 patients in the S1 group, 3 (6%) had an ascending and 47 (94%) had a descending spectral curve. Of the 42 patients in the D0 group, 37 (88.1%) had an ascending and 5 (11.9%) had a descending spectral curve. The sensitivity and specificity of water (iodine) were 0.927 and 0.836, respectively. The sensitivity and specificity of water (calcium) were 0.863 and 0.887, respectively. For different scan ranges ([0,90]; [0,120]), root mean square error (RMSE) of AIHT reconstructed image was significantly smaller than that of traditional algorithm, while peak signal-to-noise ratio (PSNR) was opposite. The differences were statistically significant (P < 0.05). In conclusion, AIHT-based CT images can better display the distribution of hepatic ascites, and the parameters of CT value, effective atomic number, water (iodine), water (calcium), and spectral curve can all provide help for the identification of hepatic ascites. Especially, water (iodine) and water (calcium) demonstrated high diagnostic performance of hepatic ascites.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Inteligencia Artificial / Yodo Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Comput Math Methods Med Asunto de la revista: INFORMATICA MEDICA Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Inteligencia Artificial / Yodo Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Comput Math Methods Med Asunto de la revista: INFORMATICA MEDICA Año: 2022 Tipo del documento: Article País de afiliación: China