Your browser doesn't support javascript.
loading
All-Solid-State Potentiometric Platforms Modified with a Multi-Walled Carbon Nanotubes for Fluoxetine Determination.
Abd-Rabboh, Hisham S M; M Hashem, Heba; M S Al Shagri, Layla; E Amr, Abdel El-Galil; Almehizia, Abdulrahman A; Naglah, Ahmed M; H Kamel, Ayman.
Afiliación
  • Abd-Rabboh HSM; Chemistry Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia.
  • M Hashem H; Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt.
  • M S Al Shagri L; Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt.
  • E Amr AE; Chemistry Department, College of Science, Sakhir 32038, Bahrain.
  • Almehizia AA; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
  • Naglah AM; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
  • H Kamel A; Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
Membranes (Basel) ; 12(5)2022 Apr 21.
Article en En | MEDLINE | ID: mdl-35629772
ABSTRACT
Novel cost-effective screen-printed potentiometric platforms for simple, fast, and accurate assessment of Fluoxetine (FLX) were designed and characterized. The potentiometric platforms integrate both the FLX sensor and the reference Ag/AgCl electrode. The sensors were based on the use of 4'-nitrobenzo-15-crown-5 (ionophore I), dibenzo-18-crown-6 (ionophore II), and 2-hydroxypropyl-ß-cyclodextrin (2-HP-ß-CD) (ionophore III) as neutral carriers within a plasticized PVC matrix. Multiwalled carbon nanotubes (MWCNTs) were used as a lipophilic ion-to-electron transducing material and sodium tetrakis [3,5-bis(trifluoromethyl)phenyl] borate (NaTFPB) was used as an anionic excluder. The presented platforms revealed near-Nernstian potentiometric response with slopes of 56.2 ± 0.8, 56.3 ± 1.7 and 64.4 ± 0.2 mV/decade and detection limits of 5.2 × 10-6, 4.7 × 10-6 and 2.0 × 10-7 M in 10 mM Tris buffer solution, pH 7 for sensors based on ionophore I, II, and III, respectively. All measurements were carried out in 10 mM tris buffer solution at pH 7.0. The interfacial capacitance before and after insertion of the MWCNTs layer was evaluated for the presented sensors using the reverse-current chronopotentiometry. The sensors were introduced for successful determination of FLX drug in different pharmaceutical dosage forms. The results were compared with those obtained by the standard HPLC method. Recovery values were calculated after spiking fixed concentrations of FLX in different serum samples. The presented platforms can be potentially manufacturable at large scales and provide a portable, rapid, disposable, and cost-effective analytical tool for measuring FLX.