Your browser doesn't support javascript.
loading
Added value of mass characteristic frequency to 2-D shear wave elastography for differentiation of benign and malignant thyroid nodules.
Kohlenberg, Jacob; Gu, Juanjuan; Parvinian, Ahmad; Webb, Jeremy; Kawkgi, Omar El; Larson, Nicholas B; Ryder, Mabel; Fatemi, Mostafa; Alizad, Azra.
Afiliación
  • Kohlenberg J; Division of Endocrinology, Department of Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN, USA; Division of Diabetes, Department of Medicine, Endocrinology and Metabolism, University of Minnesota, Minneapolis, MN, USA.
  • Gu J; Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, USA.
  • Parvinian A; Department of Radiology, Mayo Clinic College of Medicine and Science, 200 First Street SW, Rochester, MN 55905, USA.
  • Webb J; Department of Radiology, Mayo Clinic College of Medicine and Science, 200 First Street SW, Rochester, MN 55905, USA.
  • Kawkgi OE; Division of Endocrinology, Department of Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN, USA.
  • Larson NB; Department of Quantitative Health Sciences, Mayo Clinic College of Medicine and Science, Rochester, MN, USA.
  • Ryder M; Division of Endocrinology, Department of Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN, USA.
  • Fatemi M; Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, USA.
  • Alizad A; Department of Radiology, Mayo Clinic College of Medicine and Science, 200 First Street SW, Rochester, MN 55905, USA. Electronic address: Alizad.Azra@mayo.edu.
Ultrasound Med Biol ; 48(8): 1663-1671, 2022 08.
Article en En | MEDLINE | ID: mdl-35672198
ABSTRACT
Mass characteristic frequency (fmass) is a novel shear wave (SW) parameter that represents the ratio of the averaged minimum SW speed within the regions of interest to the largest dimension of the mass. Our study objective was to evaluate if the addition of fmass to conventional 2-D shear wave elastography (SWE) parameters would improve the differentiation of benign from malignant thyroid nodules. Our cohort comprised 107 patients with 113 thyroid nodules, of which 67 (59%) were malignant. Two-dimensional SWE data were obtained using the Supersonic Imagine Aixplorer ultrasound system equipped with a 44- to 15-MHz15-MHz linear array transducer. A receiver operating characteristic curve was generated based on a multivariable logistic regression analysis to evaluate the ability of SWE parameters with/without fmass and with/without clinical factors to discriminate benign from malignant thyroid nodules. The addition of fmass to conventional SW elasticity parameters increased the area under the curve from 0.808 to 0.871 (p = 0.02). The combination of SW elasticity parameters plus fmass plus clinical factors provided the strongest thyroid nodule malignancy probability estimate, with a sensitivity of 93.4% and specificity of 91.1% at the optimal threshold. In summary, fmass can be a valuable addition to conventional 2-D SWE parameters.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Tiroides / Nódulo Tiroideo / Diagnóstico por Imagen de Elasticidad Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Ultrasound Med Biol Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Tiroides / Nódulo Tiroideo / Diagnóstico por Imagen de Elasticidad Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Ultrasound Med Biol Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos