Your browser doesn't support javascript.
loading
Correlation Between Enlargement of Retinal Nerve Fiber Defect Angle in En Face Imaging and Visual Field Progression.
Takahashi, Naoki; Omodaka, Kazuko; Nakazawa, Arata; Kikawa, Tsutomu; Ninomiya, Takahiro; Kiyota, Naoki; Tsuda, Satoru; Himori, Noriko; Akiba, Masahiro; Nakazawa, Toru.
Afiliación
  • Takahashi N; Department of Ophthalmology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Omodaka K; Department of Ophthalmology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Nakazawa A; Department of Ophthalmology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Kikawa T; Research & Development Div., Topcon Corporation, Tokyo, Japan.
  • Ninomiya T; Department of Ophthalmology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Kiyota N; Department of Ophthalmology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Tsuda S; Department of Ophthalmology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Himori N; Department of Ophthalmology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Akiba M; Department of Aging Vision Healthcare, Tohoku University Graduate School of Biomedical Engineering, Sendai, Miyagi, Japan.
  • Nakazawa T; Research & Development Div., Topcon Corporation, Tokyo, Japan.
Transl Vis Sci Technol ; 11(6): 8, 2022 06 01.
Article en En | MEDLINE | ID: mdl-35675064
Purpose: Retinal nerve fiber layer defects (RNFLDs) become enlarged with glaucoma progression. We measured the RNFLD angle and investigated whether it was correlated with deterioration of the visual field in patients with glaucoma. Methods: This study included 84 eyes of 84 patients with open-angle glaucoma (mean deviation [MD] = -6.51 ± 5.91 dB, follow-up period = 2.82 ± 0.74 years) with the RNFLDs, who underwent en face swept-source optical coherence tomography (SS-OCT) wide scans (12 × 9 mm) at least 6 times. The RNFLD angle was measured as the intersection between the RNFLD and a circle centered on the disc with a radius half the distance between the disc and the fovea. Slopes for the RNFLD angle, macular ganglion cell layer thickness (GCCT), and circumpapillary RNFL thickness (cpRNFLT) were compared with the MD slope, as measured with the Humphrey field analyzer 24-2 program. Results: The correlation coefficients with MD slope were -0.67 for the RNFLD angle slope (P < 0.001), 0.15 for the macular GCCT slope (P = 0.163), and 0.04 for the cpRNFLT slope (P = 0.719). The RNFLD angle tended to increase as the number of disc hemorrhage occurrences increased (rs = 0.31, P = 0.004). The RNFLD angle slope also had good predictive power for glaucoma progression (area under the receiver operating characteristic curve = 0.88, 95% confidence interval = 0.81-0.95). Conclusions: We found that the RNFLD angle slope was more closely associated with the MD slope than were other OCT parameters. This suggests that measurement of the RNFLD angle with en face OCT images could be effective in evaluating glaucoma progression. Translational Relevance: Our study provides a method for monitoring glaucoma progression with SS-OCT.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedades de la Retina / Glaucoma / Glaucoma de Ángulo Abierto Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Transl Vis Sci Technol Año: 2022 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedades de la Retina / Glaucoma / Glaucoma de Ángulo Abierto Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Transl Vis Sci Technol Año: 2022 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos