Aortic Sinus Contrast Retention During TAVR: A Warning Sign Preceding a Potential Thrombotic Complication.
JACC Case Rep
; 4(11): 666-670, 2022 Jun 01.
Article
en En
| MEDLINE
| ID: mdl-35677788
ABSTRACT
Sinus contrast material retention after transcatheter aortic valve replacement (TAVR) is a rare phenomenon that may reflect an increased risk for thrombotic complications. We present 3 cases of persistent contrast agent retention in the sinus of Valsalva during the TAVR procedure that portend the occurrence of embolic stroke or bioprosthetic valve thrombosis. (Level of Difficulty Advanced.).