Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi.
Szymanska, Beata; Lukaszewski, Zenon; Oldak, Lukasz; Zelazowska-Rutkowska, Beata; Hermanowicz-Szamatowicz, Kinga; Gorodkiewicz, Ewa.
Afiliación
  • Szymanska B; Bioanalysis Laboratory, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, Poland.
  • Lukaszewski Z; Faculty of Chemical Technology, Poznan University of Technology, pl. Sklodowskiej-Curie 5, 60-965 Poznan, Poland.
  • Oldak L; Bioanalysis Laboratory, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, Poland.
  • Zelazowska-Rutkowska B; Doctoral School of Exact and Natural Science, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, Poland.
  • Hermanowicz-Szamatowicz K; Department of Pediatric Laboratory Diagnostics, Medical University of Bialystok, Waszyngtona 17, 15-274 Bialystok, Poland.
  • Gorodkiewicz E; Department of Clinical Oncology, Comprehensive Cancer Center, Ogrodowa 12, 15-027 Bialystok, Poland.
Biosensors (Basel) ; 12(6)2022 Jun 14.
Article en En | MEDLINE | ID: mdl-35735559
ABSTRACT
Interleukin-6 (IL-6) is a biomarker of inflammation, the advanced stage of COVID-19, and several cancers, including ovarian cancer. Two biosensors for the determination of IL-6 in blood plasma by array SPRi have been developed. One of these biosensors consists of the mouse monoclonal anti-IL-6 antibody as the receptor immobilized via the cysteamine linker. The second contains galiellalactone as the receptor, being an inhibitor specific for IL-6, immobilized via octadecanethiol (ODM) as the linker. Both biosensors are specific for IL-6. The biosensor with the antibody as the receptor gives a linear analytical response between 3 (LOQ) and 20 pg mL-1 and has a precision between 8% and 9.8% and recovery between 97% and 107%, depending on the IL-6 concentration. The biosensor with galiellalactone as the receptor gives a linear analytical response between 1.1 (LOQ) and 20 pg mL-1, and has a precision between 3.5% and 9.3% and recovery between 101% and 105%, depending on IL-6 concentration. Both biosensors were validated. Changes in IL-6 concentration in blood plasma before and after resection of ovarian tumor and endometrial cyst, as determined by the two developed biosensors, are given as an example of a real clinical application.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Ováricas / Técnicas Biosensibles / COVID-19 Límite: Animals / Female / Humans Idioma: En Revista: Biosensors (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Polonia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias Ováricas / Técnicas Biosensibles / COVID-19 Límite: Animals / Female / Humans Idioma: En Revista: Biosensors (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Polonia