Your browser doesn't support javascript.
loading
A Cohort Study of Free Light Chain Ratio in Combination with Serum Protein Electrophoresis as a First-Line Test in General Practice.
Sandfeld-Paulsen, Birgitte; Aggerholm-Pedersen, Ninna; Samson, Mie Hessellund; Møller, Holger Jon.
Afiliación
  • Sandfeld-Paulsen B; Department of Clinical Biochemistry, Aarhus University Hospital, 8200 Aarhus, Denmark.
  • Aggerholm-Pedersen N; Department of Oncology, Aarhus University Hospital, 8200 Aarhus, Denmark.
  • Samson MH; Department of Experimental Oncology, Aarhus University Hospital, 8200 Aarhus, Denmark.
  • Møller HJ; Department of Clinical Biochemistry, Aarhus University Hospital, 8200 Aarhus, Denmark.
Cancers (Basel) ; 14(12)2022 Jun 14.
Article en En | MEDLINE | ID: mdl-35740597
Multiple Myeloma (MM) often present with unspecific symptoms, which can lead to diagnostic delay. Serum-free light chain (sFLC) ratio is suggested to replace urine protein electrophoresis (UPE) in the diagnostic work-up of myeloma. We aimed to investigate the performance of the sFLC-ratio in general practice (GP) compared to UPE, just as we explored different sFLC-ratio cut-offs' influence on diagnostic values. In a cohort of 13,210 patients from GP measures of sFLC-ratio, serum protein electrophoresis (SPE), or UPE were compared to diagnoses of incident M-component related diseases acquired from Danish health registers. UPE and sFLC-ratio equally improved diagnostic values when combined with SPE (sensitivity: SPE and UPE: 95.6 (90.6-98.4); SPE and sFLC-ratio: 95.1 (90.2-98.0)). The addition of the sFLC-ratio to SPE resulted in the identification of 13 patients with MGUS, light chain disease and amyloidosis, which was in line with the addition of UPE to SPE. The number of false-positive tests was UPE and SPE: 364 (11%) and sFLC-ratio and SPE: 677(19%). Expanding sFLC-ratio reference range to 0.26-4.32 resulted in a significant reduction in false positives n = 226 (6%) without loss of patients with clinical plasma cell dyscrasias. sFLC-ratio improves the diagnostic value of SPE in GP. However, due to low specificity and a large number of false positives, expanded cut-off values should be considered.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Etiology_studies / Observational_studies Idioma: En Revista: Cancers (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Dinamarca Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Etiology_studies / Observational_studies Idioma: En Revista: Cancers (Basel) Año: 2022 Tipo del documento: Article País de afiliación: Dinamarca Pais de publicación: Suiza