Your browser doesn't support javascript.
loading
Mechanical, corrosion, nanotribological, and biocompatibility properties of equal channel angular pressed Ti-28Nb-35.4Zr alloys for biomedical applications.
Munir, Khurram; Lin, Jixing; Wright, Paul F A; Ozan, Sertan; Li, Yuncang; Wen, Cuie.
Afiliación
  • Munir K; School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia.
  • Lin J; School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China.
  • Wright PFA; School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria 3083, Australia.
  • Ozan S; School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia; Department of Mechanical Engineering, Yozgat Bozok University, Yozgat 66100, Turkey.
  • Li Y; School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia.
  • Wen C; School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia. Electronic address: cuie.wen@rmit.edu.au.
Acta Biomater ; 149: 387-398, 2022 09 01.
Article en En | MEDLINE | ID: mdl-35817341
ABSTRACT
This study systematically investigated the effect of equal channel angular pressing (ECAP) on the microstructure, mechanical, corrosion, nano-tribological properties and biocompatibility of a newly developed ß Ti-28Nb-35.4Zr (hereafter denoted TNZ) alloy. Results indicated that ECAP of the ß TNZ alloy refined its microstructure by forming ultrafine grains without causing stress-induced phase transformation, leading to formation of a single ß phase. The ECAP-processed TNZ alloy exhibited a compressive yield strength of 960 MPa, and high plastic deformation capacity without fracturing under compression loads. Potentiodynamic polarization tests revealed the higher tendency of ECAP-processed TNZ alloys to form passive oxide films on its surface, which exhibited a lower corrosion rate (0.44±0.07 µm/y) in Hanks' balanced salt solution compared to its as-cast counterpart (0.71±0.10 µm/y). Nanotribological testing also revealed higher resistance of the ECAP-processed TNZ alloy to abrasion, wear and scratching, when compared to its as-cast counterpart. Cytocompatibility and cell adhesion assessments of the ECAP-processed TNZ alloys showed a high viability (111%) of human osteoblast-like SaOS2 cells after 7 d of culturing. Moreover, the ECAP-processed TNZ alloy promoted adhesion and spreading of SaOS2 cells, which exhibited growth and proliferation on alloy surfaces. In summary, significantly enhanced mechanical, corrosion, and biological properties of ECAP-processed TNZ alloy advocate its suitability for load-bearing implant applications. STATEMENT OF

SIGNIFICANCE:

Equal channel angular pressing (ECAP) provides a unique combination of enhanced mechanical and functional properties of materials by optimizing their microstructures and phase transformations. This study investigated the mechanical, nano-tribological, corrosion, and biocompatibility properties of a newly developed ß Ti-28Nb-35.4Zr (TNZ) alloy processed via ECAP. Our findings indicated that ECAP of the ß TNZ alloy refined its microstructure by forming ultrafine grains without causing stress-induced phase transformation. Compared to its as-cast counterpart, ECAP-processed TNZ exhibited significantly enhanced compressive yield strength, plastic deformation capacity, hardness, wear, and corrosion properties. Moreover, in vitro cytocompatibility and cell adhesion studies revealed high cellular viabilities, growth and proliferation of osteoblast-like SaOS2 cells on the ECAP-processed TNZ alloy.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Titanio / Aleaciones Límite: Humans Idioma: En Revista: Acta Biomater Año: 2022 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Titanio / Aleaciones Límite: Humans Idioma: En Revista: Acta Biomater Año: 2022 Tipo del documento: Article País de afiliación: Australia