Your browser doesn't support javascript.
loading
Diffusion Tensor Imaging Radiomics for Diagnosis of Parkinson's Disease.
Li, Jingwen; Liu, Xiaoming; Wang, Xinyi; Liu, Hanshu; Lin, Zhicheng; Xiong, Nian.
Afiliación
  • Li J; Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China.
  • Liu X; Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China.
  • Wang X; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China.
  • Liu H; Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China.
  • Lin Z; Department of Neurology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China.
  • Xiong N; Laboratory of Psychiatric Neurogenomics, McLean Hospital, Harvard Medical School, Belmont, MA 02478, USA.
Brain Sci ; 12(7)2022 Jun 29.
Article en En | MEDLINE | ID: mdl-35884658
BACKGROUND: Diagnosis of Parkinson's Disease (PD) based on clinical symptoms and scale scores is mostly objective, and the accuracy of neuroimaging for PD diagnosis remains controversial. This study aims to introduce a radiomic tool to improve the sensitivity and specificity of diagnosis based on Diffusion Tensor Imaging (DTI) metrics. METHODS: In this machine learning-based retrospective study, we collected basic clinical information and DTI images from 54 healthy controls (HCs) and 56 PD patients. Among them, 60 subjects (30 PD patients and 30 HCs) were assigned to the training group, whereas the test cohort was 26 PD patients and 24 HCs. After the feature extraction and selection using newly developed image processing software Ray-plus, LASSO regression was used to finalize radiomic features. RESULTS: A total of 4600 radiomic features were extracted, of which 12 were finally selected. The values of the AUC (area under the subject operating curve) in the training group, the validation group, and overall were 0.911, 0.931, and 0.919, respectively. CONCLUSION: This study introduced a novel radiometric and computer algorithm based on DTI images, which can help increase the sensitivity and specificity of PD screening.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Observational_studies Idioma: En Revista: Brain Sci Año: 2022 Tipo del documento: Article País de afiliación: China Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Observational_studies Idioma: En Revista: Brain Sci Año: 2022 Tipo del documento: Article País de afiliación: China Pais de publicación: Suiza