Your browser doesn't support javascript.
loading
Hemin-graphene oxide-gold nanoflower-assisted enhanced electrochemiluminescence immunosensor for determination of prostate-specific antigen.
Liu, Gengjun; Guan, Xiaohan; Li, Binxiao; Zhou, Hong; Kong, Na; Wang, Haiyan.
Afiliación
  • Liu G; Department of Blood Transfusion, The Affiliated Hospital of Qingdao University, Qingdao, 266042, People's Republic of China.
  • Guan X; Clinical Medicine Department, Medical College, Qingdao University, Qingdao, 266071, People's Republic of China.
  • Li B; Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular, Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai, 200433, People's Republic of China.
  • Zhou H; Department of Blood Transfusion, The Affiliated Hospital of Qingdao University, Qingdao, 266042, People's Republic of China. zhouhong@qust.edu.cn.
  • Kong N; Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, People's Republic of China. zhouhong@qust.edu.cn.
  • Wang H; Agricultural Products Processing Research Institute, Chinese Academy of Tropical Agricultural Sciences, Zhanjiang, 524001, People's Republic of China. kongna109101@126.com.
Mikrochim Acta ; 189(8): 297, 2022 07 28.
Article en En | MEDLINE | ID: mdl-35900602
An ultrasensitive luminol electrochemiluminescence (ECL) immunosensor was constructed for the detection of prostate specific antigen (PSA) using glucose oxidase-decorated hemin-graphene oxide-gold nanoflowers ternary nanocomposites as probes. Graphene oxide was first modified with hemin and then with gold nanoflowers through an in situ growth method, which has significantly boosted the catalytic activity of this graphene oxide-based peroxidase mimetics. The biocatalytical activity of this ECL immunosensor was thoroughly investigated to achieve selective recognition of the analyte molecules (PSA) by specific binding between antigens and antibodies. The limit of detection was calculated to be 0.32 pg mL-1 with a signal-to-noise ratio of 3. A broad linear range from 7.5 × 10-4 to 2.5 ng mL-1 was obtained. Such step-by-step assembled biosensor showed controlled nanostructure and exhibited promising application in analysis of human serum samples with a recovery range of 90.6-111.8% and a RSD range of 3.9-5.5%.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Nanocompuestos Límite: Humans / Male Idioma: En Revista: Mikrochim Acta Año: 2022 Tipo del documento: Article Pais de publicación: Austria

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Nanocompuestos Límite: Humans / Male Idioma: En Revista: Mikrochim Acta Año: 2022 Tipo del documento: Article Pais de publicación: Austria