Nierhaus, Axel; Morales, Jesus; Wendt, Daniel; Scheier, Jörg; Gutzler, Dominik; Jarczak, Dominik; Born, Frank; Hagl, Christian; Deliargyris, Efthymios; Mehta, Yatin.
Afiliación
  • Nierhaus A; Clinic for Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg, Hamburg, Germany.
  • Morales J; Department of Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Wendt D; CytoSorbents, Princeton, NJ, USA.
  • Scheier J; CytoSorbents, Princeton, NJ, USA.
  • Gutzler D; Department of Thoracic and Cardiovascular Surgery, West German Heart and Vascular Center Essen, Essen, Germany.
  • Jarczak D; CytoSorbents, Princeton, NJ, USA.
  • Born F; CytoSorbents, Princeton, NJ, USA.
  • Hagl C; Clinic for Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg, Hamburg, Germany.
  • Deliargyris E; Department of Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Mehta Y; Department of Cardiac Surgery, University Hospital, LMU Munich, Munich, Germany.
Minim Invasive Ther Allied Technol ; 31(7): 1058-1065, 2022 Oct.
Article en En | MEDLINE | ID: mdl-35913784
INTRODUCTION: We performed an analysis of two blood purification systems to determine their performance for removing interleukins (ILs)-6 and 10, tumor necrosis factor (TNF)-α and monocyte chemoattractant protein (MCP)-1 from blood. MATERIAL AND METHODS: An in vitro hemoperfusion blood recirculation circuit was used to compare the CytoSorb® 300 mL (CytoSorbents Inc., Princeton, NJ) and Jafron HA 380 (Jafron Biomedical Co., Ltd., Zhuhai City, China) devices. The removal of purified recombinant human IL-6, IL-10, TNFα and MCP-1 by the adsorbers was compared at various timepoints. Three runs were completed and removal was evaluated as the mean area under the curve (AUC). RESULTS: Both devices showed effective removal of the tested cytokines. IL-6, IL-10, TNFα and MCP-1 were removed faster and to a higher extent by the CytoSorb® 300 mL device. At maximal time of 12 h, overall removal according to AUC of remaining concentrations was significantly lower with CytoSorb® 300 mL compared with HA 380 (IL-6: 1075.5 ± 665.9 vs. 4345.1 ± 1499.3 (p = 0.01), IL-10: 5065.7 ± 882.5 vs. 11,939.7 ± 4523.1 (p = 0.03), TNF-α: 6519.9 ± 997.6 vs. 10,303.7 ± 2347.0 (p = 0.03) and MCP-1: 278.9 ± 40.7 vs. 607.3 ± 84.4 (p = 0.001)). CONCLUSIONS: Both the CytoSorb® and the Jafron HA 380 devices are capable of removing cytokines from blood in a benchtop model. The CytoSorb® 300 device was significantly more efficient achieving the bulk of the removal in the first 120 min.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hemoperfusión / Interleucina-10 Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Minim Invasive Ther Allied Technol Asunto de la revista: TERAPEUTICA Año: 2022 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hemoperfusión / Interleucina-10 Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Minim Invasive Ther Allied Technol Asunto de la revista: TERAPEUTICA Año: 2022 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Reino Unido