Your browser doesn't support javascript.
loading
Setup uncertainties and appropriate setup margins in the head-tilted supine position of whole-brain radiotherapy (WBRT).
Park, Jae Won; Yea, Ji Woon; Park, Jaehyeon; Oh, Se An.
Afiliación
  • Park JW; Department of Radiation Oncology, Yeungnam University Medical Center, Daegu, Korea.
  • Yea JW; Department of Radiation Oncology, Yeungnam University College of Medicine, Daegu, Korea.
  • Park J; Department of Radiation Oncology, Yeungnam University Medical Center, Daegu, Korea.
  • Oh SA; Department of Radiation Oncology, Yeungnam University College of Medicine, Daegu, Korea.
PLoS One ; 17(8): e0271077, 2022.
Article en En | MEDLINE | ID: mdl-35925916
ABSTRACT
Various applications of head-tilting techniques in whole-brain radiotherapy (WBRT) have been introduced. However, a study on the setup uncertainties and margins in head-tilting techniques has not been reported. This study evaluated the setup uncertainties and determined the appropriate planning target volume (PTV) margins for patients treated in the head-tilted supine (ht-SP) and conventional supine position (c-SP) in WBRT. Thirty patients who received WBRT at our institution between October 2020 and May 2021 in the c-SP and ht-SP were investigated. The DUON head mask (60124, Orfit Industries, Wijnegem, Belgium) was used in the c-SP, and a thermoplastic U-Frame Mask (R420U, Klarity Medical & Equipment Co. Ltd., Lan Yu, China) was used in the ht-SP. Daily setup verification using planning computed tomography (CT) and cone-beam CT was corrected for translational (lateral, longitudinal, and vertical) and rotational (yaw) errors. In the c-SP, the means of systematic errors were -0.80, 0.79, and 0.37 mm and random errors were 0.27, 0.54, and 0.39 mm in the lateral, longitudinal, and vertical translational dimensions, respectively. Whereas, for the ht-SP, the means of systematic errors were -0.07, 0.73, and -0.63 mm, and random errors were 0.75, 1.39, 1.02 mm in the lateral, longitudinal, and vertical translational dimensions, respectively. The PTV margins were calculated using Stroom et al.'s [2Σ+0.7σ] and van Herk et al.'s recipe [2.5Σ+0.7σ]. Appropriate PTV margins with van Herk et al.'s recipe in WBRT were <2 mm and 1.5° in the c-SP and <3 mm and 2° in the ht-SP in the translational and rotational directions, respectively. Although the head tilt in the supine position requires more margin, it can be applied as a sufficiently stable and effective position in radiotherapy.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Planificación de la Radioterapia Asistida por Computador / Radioterapia Guiada por Imagen Límite: Humans Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Planificación de la Radioterapia Asistida por Computador / Radioterapia Guiada por Imagen Límite: Humans Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2022 Tipo del documento: Article