Your browser doesn't support javascript.
loading
Utilizing machine learning for opportunistic screening for low BMD using CT scans of the cervical spine.
Sebro, Ronnie; De la Garza-Ramos, Cynthia.
Afiliación
  • Sebro R; Department of Radiology, Mayo Clinic, Jacksonville, FL 32224; Center for Augmented Intelligence, Mayo Clinic, Jacksonville, FL 32224. Electronic address: Sebro.ronnie@mayo.edu.
  • De la Garza-Ramos C; Department of Radiology, Mayo Clinic, Jacksonville, FL 32224.
J Neuroradiol ; 50(3): 293-301, 2023 May.
Article en En | MEDLINE | ID: mdl-36030924
ABSTRACT

BACKGROUND:

Computed Tomography (CT) scans of the cervical spine are often performed to evaluate patients for trauma and degenerative changes of the cervical spine. We hypothesized that the CT attenuation of the cervical vertebrae can be used to identify patients who should be screened for osteoporosis.

METHODS:

A retrospective study of 253 patients (177 training/validation and 76 test) with unenhanced CT scans of the cervical spine and Dual-energy x-ray Absorbtiometry (DXA) studies within 12 months of each other was performed. Volumetric segmentation of C1-T1, clivus, and first ribs was performed to obtain the CT attenuation of each bone. The correlations of the CT attenuations between the bones and with DXA measurements were evaluated. Univariate receiver operator characteristic (ROC) analyses, and multivariate classifiers (Random Forest (RF), XGBoost, Naïve Bayes (NB), and Support Vector Machines (SVM)) analyzing the CT attenuation of all bones, were utilized to predict patients with osteopenia/osteoporosis and femoral neck bone mineral density (BMD) T-scores <-1.

RESULTS:

There were positive correlations between the CT attenuation of each bone, and with the DXA measurements. A CT attenuation threshold of 305.2 Hounsfield Units (HU) at C3 had the highest accuracy (0.763, AUC=0.814) to detect femoral neck BMD T-scores ≤-1 and a CT attenuation threshold of 323.6 HU at C3 had the highest accuracy (0.774, AUC=0.843) to detect osteopenia/osteoporosis. The SVM classifier (AUC=0.756) had higher AUC than the RF (AUC=0.692, P=0.224), XGBoost (AUC=0.736; P=0.814), NB (AUC=0.622, P=0.133) and CT threshold of 305.2 HU at C3 (AUC=0.704, P=0.531) classifiers to identify patients with femoral neck BMD T-scores <-1. The SVM classifier (accuracy=0.816) was more accurate than using the CT threshold of 305.2 HU at C3 (accuracy=0.671) (McNemar's χ12=7.55, P=0.006).

CONCLUSION:

Opportunistic screening for low BMD can be done using cervical spine CT scans. A SVM classifier was more accurate than using the CT threshold of 305.2 HU at C3.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteoporosis / Enfermedades Óseas Metabólicas Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Límite: Humans Idioma: En Revista: J Neuroradiol Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteoporosis / Enfermedades Óseas Metabólicas Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Límite: Humans Idioma: En Revista: J Neuroradiol Año: 2023 Tipo del documento: Article