A Novel Cost-Effective Simulation Model for Continuous Curvilinear Capsulorhexis.
Clin Ophthalmol
; 16: 2759-2764, 2022.
Article
en En
| MEDLINE
| ID: mdl-36046573
ABSTRACT
Introduction:
We describe and validate a low-cost simulation model for practicing anterior lens capsule continuous curvilinear capsulorhexis (CCC).Methods:
A simulation model for CCC was developed from widely available low-cost materials. Ophthalmologists attending the annual scientific meeting of the Research Institute of Ophthalmology, Giza, Egypt, were asked to perform a five CCC model task and then anonymously answer a questionnaire that assessed the realism and training utility of the model using a five-point Likert scale (1 = unacceptable, 2 = poor, 3 = acceptable, 4 = favorable and 5 = excellent).Results:
Twenty-seven ophthalmologists completed the task and the anonymous questionnaire. Overall, participants felt that the model simulated CCC step in cataract surgery well (mean 3.5) and was comparable to other kinds of CCC simulation models (mean 3.3). The model scored highly for its overall educational value (mean 4.00) and for enlarging a small CCC (mean3.7), while the feasibility of this model in practicing the management of a runaway leading edge of CCC scored 2.9.Conclusion:
This model may provide an alternative method for training for CCC and other anterior lens capsule-related maneuvers. This option may be particularly helpful for residency training programs with limited access to virtual reality simulators or commercially available synthetic eye models.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Tipo de estudio:
Health_economic_evaluation
/
Prognostic_studies
Idioma:
En
Revista:
Clin Ophthalmol
Año:
2022
Tipo del documento:
Article
País de afiliación:
Egipto