Your browser doesn't support javascript.
loading
Ultrasound features and preoperative accuracy of the fine needle aspiration biopsy in detection of thyroid carcinomas.
Makazlieva, Tanja; Stoilovska Rizova, Bojana; Stojanoski, Sinisa; Manevska, Nevena; Vaskova, Olivija; Velikj Stefanovska, Vesna; Miladinova, Daniela.
Afiliación
  • Makazlieva T; Institute of Pathophysiology and Nuclear Medicine, Medical Faculty, University Ss Cyril and Methodius, Skopje, Republic of North Macedonia.
  • Stoilovska Rizova B; Institute of Pathophysiology and Nuclear Medicine, Medical Faculty, University Ss Cyril and Methodius, Skopje, Republic of North Macedonia.
  • Stojanoski S; Institute of Pathophysiology and Nuclear Medicine, Medical Faculty, University Ss Cyril and Methodius, Skopje, Republic of North Macedonia.
  • Manevska N; Medical Faculty, Lazarski University, Warsaw, Poland.
  • Vaskova O; Institute of Pathophysiology and Nuclear Medicine, Medical Faculty, University Ss Cyril and Methodius, Skopje, Republic of North Macedonia.
  • Velikj Stefanovska V; Institute of Pathophysiology and Nuclear Medicine, Medical Faculty, University Ss Cyril and Methodius, Skopje, Republic of North Macedonia.
  • Miladinova D; Institute of Epidemiology and Biostatistics with Medical Informatics, Medical Faculty, University Ss Cyril and Methodius, Skopje, Republic of North Macedonia.
J Clin Ultrasound ; 50(9): 1338-1344, 2022 Nov.
Article en En | MEDLINE | ID: mdl-36129366
ABSTRACT

OBJECTIVE:

To analyze the ultrasound (US) characteristics and fine needle biopsy (FNAB) of thyroid carcinomas (TCs) prior to surgery and compare with postoperative histopathology and to determine FNAB sensitivity and specificity. MATERIAL AND

METHODS:

Retrospective analysis of the US data during 1999-2015 was performed, as well as analysis of FNAB results and using histopathology report as "gold standard" the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of this method was evaluated.

RESULTS:

Data revealed that tumors >51 mm were declining by 50% in the period 2011-2015 compared to 2005-2010 or by 18% 2011-2015 compared to 1999-2004 and significant increase was detected in diagnosis of multicentric tumors. The analysis revealed that FNAB has sensitivity = 65.7% CI (0.59% - 0.71%) and specificity = 50% CI (0.43%-0.56%), PPV = 56.9% and NPV = 59.2%.

CONCLUSION:

We found increasing detection of smaller TCs, as well as more frequent detection of multicentricity of the neoplastic foci. FNAB results in our study revealed low sensitivity and specificity. Major limitation of the study was inability to exactly separate US guided from non US guided FNAB in evaluation of the sensitivity and specificity, due to retrospective nature of the analysis. Further studies evaluating only US guided FNAB should be performed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Tiroides / Nódulo Tiroideo Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Clin Ultrasound Año: 2022 Tipo del documento: Article Pais de publicación: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Tiroides / Nódulo Tiroideo Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Clin Ultrasound Año: 2022 Tipo del documento: Article Pais de publicación: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA