Your browser doesn't support javascript.
loading
Noninvasive shape-fitting method quantifies cam morphology in femoroacetabular impingement syndrome: Implications for diagnosis and surgical planning.
Guidetti, Martina; Malloy, Philip; Alter, Thomas D; Newhouse, Alexander C; Nho, Shane J; Espinoza Orías, Alejandro A.
Afiliación
  • Guidetti M; Section of Young Adult Hip Surgery, Department of Orthopedic Surgery, Division of Sports Medicine, Rush Medical College of Rush University, Rush University Medical Center, Chicago, Illinois, USA.
  • Malloy P; Section of Young Adult Hip Surgery, Department of Orthopedic Surgery, Division of Sports Medicine, Rush Medical College of Rush University, Rush University Medical Center, Chicago, Illinois, USA.
  • Alter TD; Department of Physical Therapy, Arcadia University, Glenside, Pennsylvania, USA.
  • Newhouse AC; Section of Young Adult Hip Surgery, Department of Orthopedic Surgery, Division of Sports Medicine, Rush Medical College of Rush University, Rush University Medical Center, Chicago, Illinois, USA.
  • Nho SJ; Section of Young Adult Hip Surgery, Department of Orthopedic Surgery, Division of Sports Medicine, Rush Medical College of Rush University, Rush University Medical Center, Chicago, Illinois, USA.
  • Espinoza Orías AA; Section of Young Adult Hip Surgery, Department of Orthopedic Surgery, Division of Sports Medicine, Rush Medical College of Rush University, Rush University Medical Center, Chicago, Illinois, USA.
J Orthop Res ; 41(6): 1256-1265, 2023 06.
Article en En | MEDLINE | ID: mdl-36227086
ABSTRACT
There are considerable limitations associated with the standard 2D imaging currently used for the diagnosis and surgical planning of cam-type femoroacetabular impingement syndrome (FAIS). The aim of this study was to determine the accuracy of a new patient-specific shape-fitting method that quantifies cam morphology in 3D based solely on preoperative MRI imaging. Preoperative and postoperative 1.5T MRI scans were performed on n = 15 patients to generate 3D models of the proximal femur, in turn used to create the actual and the virtual cam. The actual cams were reconstructed by subtracting the postoperative from the preoperative 3D model and used as reference, while the virtual cams were generated by subtracting the preoperative 3D model from the virtual shape template produced with the shape-fitting method based solely on preoperative MRI scans. The accuracy of the shape-fitting method was tested on all patients by evaluating the agreement between the metrics of height, surface area, and volume that quantified virtual and actual cams. Accuracy of the shape-fitting method was demonstrated obtaining a 97.8% average level of agreement between these metrics. In conclusion, the shape-fitting technique is a noninvasive and patient-specific tool for the quantification and localization of cam morphology. Future studies will include the implementation of the technique within a clinically based software for diagnosis and surgical planning for cam-type FAIS.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pinzamiento Femoroacetabular Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Orthop Res Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos