Operator's Influence on Contrast Agent Intravasation During Hysterosalpingo-Contrast Sonography: Explanation Based on a Physics Model.
Jin, Bin-Bin; Ma, Yan; Zhao, Xiu-Hua; Teng, Yi-Ling; Zhu, Shang-Yong.
Afiliación
  • Jin BB; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, People's Republic of China.
  • Ma Y; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, People's Republic of China.
  • Zhao XH; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, People's Republic of China.
  • Teng YL; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, People's Republic of China.
  • Zhu SY; Department of Medical Ultrasound, The First Affiliated Hospital of Guangxi Medical University, Nanning, People's Republic of China.
Int J Gen Med ; 15: 7709-7718, 2022.
Article en En | MEDLINE | ID: mdl-36238541
ABSTRACT

Objective:

To analyze the risk factors of the operators on contrast agent intravasation during hysterosalpingo-contrast sonography (HyCoSy).

Methods:

We retrospectively collected 399 infertile women who underwent HyCoSy by the same sonographer. These patients were divided into two groups according to the way how the assistants connected the syringe to the uterus radiography catheter to inject the contrast agent. We analyzed whether the use of different contrast bolus injection methods had any influence on the incidence of intravasation during HyCoSy.

Results:

There was no significant difference between the two groups with different cross-sectional areas of the syringe outflow tract in the risk variables for intravasation, but the intravasation rates of the two groups were different, 26.4% in group A and 17.1% in group B, P <0.05. The primary manifestation was that when both fallopian tubes were unobstructed, the intravasation rate of group B with smaller cross-sectional area of the outflow tract of the syringe was lower, and the difference was statistically significant. The inferences drawn from our physics model were also in line with the clinical results.

Conclusion:

The influence of different operators on the contrast agent intravasation rate of HyCoSy cannot be ignored. The assistants of HyCoSy examination should inject the contrast agent slowly and steady, and a needle can be used as a flow restrictor to control the flow into the uterine cavity per unit time, slow down the rising speed of intrauterine pressure, and avoid the accumulation of contrast agent in the uterine cavity, so as to reduce the intravasation caused by operator factors.