Paper-based colorimetric glucose sensor using Prussian blue nanoparticles as mimic peroxidase.
Tong, Liu; Wu, Lina; Zai, Yunfeng; Zhang, Yu; Su, Enben; Gu, Ning.
Afiliación
  • Tong L; State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210009, PR China; Getein Biotechnology Co., Ltd, Nanjing, 210000, China.
  • Wu L; Getein Biotechnology Co., Ltd, Nanjing, 210000, China.
  • Zai Y; Getein Biotechnology Co., Ltd, Nanjing, 210000, China.
  • Zhang Y; State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210009, PR China.
  • Su E; Getein Biotechnology Co., Ltd, Nanjing, 210000, China. Electronic address: enbens@njmu.edu.cn.
  • Gu N; State Key Laboratory of Bioelectronics, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210009, PR China. Electronic address: guning@seu.edu.cn.
Biosens Bioelectron ; 219: 114787, 2023 Jan 01.
Article en En | MEDLINE | ID: mdl-36257117
ABSTRACT
A novel paper-based colorimetric glucose sensor was proposed employing Prussian blue nanoparticles (PB NPs) as mimic peroxidase. The sensor was manufactured by spraying solution containing PB NPs, glucose oxidase and chromogenic agents into a paper, then coating the filter layer and spreading layer on the top. The layer-by-layer structure enabled the sensor detect glucose in whole blood, as well as elimination of the coffee-ring effect which ensure the performance. As a powerful alternative to natural peroxidase, PB NPs showed the mimic enzymatic activity well preserved in dry environment. The manufacture process of the sensor is easy to be industrialized. Under optimal conditions, the sensor exhibited a linear range from 2.5 mM to 25 mM for glucose in blood with satisfactory reproducibility (the coefficient of variant <4%), great storage stability (1 month at 45 °C) and excellent linearity compared with those commercial kits (R > 0.99). Coupled with a handhold device, the PB NPs-based test strip realized the goal of personal operation, user-friendly control, automatic readouts, and data storage, and able to link the Cloud, showing unique potential in clinical application, especially in community-level medical scenarios.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: China