Pacemaker after Sutureless and Rapid-Deployment Prostheses: A Progress Report from the SURD-IR.
Pollari, Francesco; Berretta, Paolo; Albertini, Alberto; Carrel, Thierry; Teoh, Kevin; Meuris, Bart; Villa, Emmanuel; Kappert, Utz; Andreas, Martin; Solinas, Marco; Misfeld, Martin; Savini, Carlo; Fiore, Antonio; Shrestha, Malakh; Santarpino, Giuseppe; Martinelli, Gian Luca; Mignosa, Carmelo; Glauber, Mattia; Yan, Tristan; Fischlein, Theodor; Di Eusanio, Marco.
Afiliación
  • Pollari F; Department of Cardiac Surgery, Cardiovascular Center, Klinikum Nürnberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany.
  • Berretta P; Department of Cardiac Surgery, Lancisi Cardiovascular Center, Polytechnic University of Marche, Ancona, Italy.
  • Albertini A; Department of Cardiovascular Surgery, Maria Cecilia Hospital GVM Care and Research, Cotignola, Italy.
  • Carrel T; Department of Cardiovascular Surgery, Inselspital University Hospital Bern, Bern, Switzerland.
  • Teoh K; Southlake Regional Health Centre, Newmarket, Ontario, Canada.
  • Meuris B; KU Leuven University Hospitals Leuven, Leuven, Flanders, Belgium.
  • Villa E; Poliambulanza Foundation Hospital Institute, Brescia, Lombardia, Italy.
  • Kappert U; Heart Centre Dresden University Hospital of the University of Technology Dresden, Dresden, Sachsen, Germany.
  • Andreas M; Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria.
  • Solinas M; Heart Hospital Pasquinucci Hospital of Massa, Massa, Toscana, Italy.
  • Misfeld M; Department of Cardiac Surgery, Heart Centre, University of Leipzig, Leipzig, Germany.
  • Savini C; Alma Mater Studiorum University of Bologna, Bologna, Emilia-Romagna, Italy.
  • Fiore A; Centre Hospitalier Universitaire Henri Mondor, Creteil, Île-de-France, France.
  • Shrestha M; Department of Thoracic and Cardiovascular Surgery, Hannover Medical School, Hannover, Germany.
  • Santarpino G; Klinik für Herzchirurgie, Klinikum Nürnberg, Nuremberg, Germany.
  • Martinelli GL; Department of Cardiovascular, Clinica S. Gaudenzio, Novara, Italy.
  • Mignosa C; ISMETT, Palermo, Sicilia, Italy.
  • Glauber M; Sant'Ambrogio Clinic, Milano, Lombardia, Italy.
  • Yan T; CORE, Athens, Ohio, United States.
  • Fischlein T; Department of Cardiac Surgery, Klinikum Nürnberg, Paracelsus Medical University, Nuremberg, Germany.
  • Di Eusanio M; Azienda Ospedaliero Universitaria Ospedali Riuniti Umberto I G M Lancisi G Salesi, Ancona, Marche, Italy.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Article en En | MEDLINE | ID: mdl-36257545
ABSTRACT

OBJECTIVES:

The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR).

METHODS:

We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019).

RESULTS:

The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time.

CONCLUSION:

Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estenosis de la Válvula Aórtica / Marcapaso Artificial / Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Procedimientos Quirúrgicos sin Sutura Tipo de estudio: Clinical_trials Límite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Año: 2023 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estenosis de la Válvula Aórtica / Marcapaso Artificial / Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas / Procedimientos Quirúrgicos sin Sutura Tipo de estudio: Clinical_trials Límite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Año: 2023 Tipo del documento: Article País de afiliación: Alemania