Your browser doesn't support javascript.
loading
Validation of a non-linear index of heart rate variability to determine aerobic and anaerobic thresholds during incremental cycling exercise in women.
Schaffarczyk, Marcelle; Rogers, Bruce; Reer, Rüdiger; Gronwald, Thomas.
Afiliación
  • Schaffarczyk M; Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Hamburg, Germany. marcelle.schaffarczyk@medicalschool-hamburg.de.
  • Rogers B; Department of Internal Medicine, College of Medicine, University of Central Florida, Boston, USA.
  • Reer R; Department Sports and Exercise Medicine, Institute of Human Movement Science, University of Hamburg, Hamburg, Germany.
  • Gronwald T; Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, University of Applied Sciences and Medical University, Hamburg, Germany.
Eur J Appl Physiol ; 123(2): 299-309, 2023 Feb.
Article en En | MEDLINE | ID: mdl-36269394
ABSTRACT
Studies highlight the usage of non-linear time series analysis of heart rate variability (HRV) using the short-term scaling exponent alpha1 of Detrended Fluctuation Analysis (DFA-alpha1) during exercise to determine aerobic and anaerobic thresholds. The present study aims to further verify this approach in women. Gas exchange and HRV data were collected from 26 female participants with different activity levels. Oxygen uptake (VO2) and heart rate (HR) at first (VT1) and second ventilatory thresholds (VT2) were compared with DFA-alpha1-based thresholds 0.75 (HRVT1) and 0.50 (HRVT2).

Results:

VO2 at VT1 and VT2 were 25.2 ml/kg/min (± 2.8) and 31.5 ml/kg/min (± 3.6) compared with 26.5 ml/kg/min (± 4.0) and 31.9 ml/kg/min (± 4.5) for HRVT1 and HRVT2, respectively (ICC3,1 = 0.77, 0.84; r = 0.81, 0.86, p < 0.001). The mean HR at VT1 was 147 bpm (± 15.6) and 167 bpm (± 12.7) for VT2, compared with 152 bpm (± 15.5) and 166 bpm (± 13.2) for HRVT1 and HRVT2, respectively (ICC3,1 = 0.87, 0.90; r = 0.87, 0.90, p < 0.001). Bland-Altman analysis for VT1 vs. HRVT1 showed a mean difference of - 1.3 ml/kg/min (± 2.4; LoA 3.3, - 6.0 ml/kg/min) for VO2 and of - 4.7 bpm (± 7.8; LoA 10.6, - 20.0 bpm) for HR. VT2 vs. HRVT2 showed a mean difference of - 0.4 ml/kg/min (± 2.3; LoA 4.1, - 4.9 ml/kg/min) for VO2 and 0.5 bpm (± 5.7; LoA 11.8, - 10.8 bpm) for HR. DFA-alpha1-based thresholds showed good agreement with traditionally used thresholds and could be used as an alternative approach for marking organismic transition zones for intensity distribution in women.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Consumo de Oxígeno / Umbral Anaerobio Límite: Female / Humans Idioma: En Revista: Eur J Appl Physiol Asunto de la revista: FISIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Consumo de Oxígeno / Umbral Anaerobio Límite: Female / Humans Idioma: En Revista: Eur J Appl Physiol Asunto de la revista: FISIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Alemania