Your browser doesn't support javascript.
loading
Quantitation of Venetoclax in Human Plasma by High-Performance Liquid Chromatography with Ultraviolet Detection.
Fukuda, Natsuki; Kobayashi, Takahiro; Sato, Honami; Akamine, Yumiko; Takahashi, Naoto; Miura, Masatomo.
Afiliación
  • Fukuda N; Department of Pharmacy, Akita University Hospital, Akita, 010-8543, Japan.
  • Kobayashi T; Department of Hematology, Nephrology, and Rheumatology, Akita University Graduate School of Medicine, Akita, 010-8543, Japan.
  • Sato H; Department of Hematology, Nephrology, and Rheumatology, Akita University Graduate School of Medicine, Akita, 010-8543, Japan.
  • Akamine Y; Department of Pharmacy, Akita University Hospital, Akita, 010-8543, Japan.
  • Takahashi N; Department of Hematology, Nephrology, and Rheumatology, Akita University Graduate School of Medicine, Akita, 010-8543, Japan.
  • Miura M; Department of Pharmacy, Akita University Hospital, Akita, 010-8543, Japan.
J Chromatogr Sci ; 2022 Oct 31.
Article en En | MEDLINE | ID: mdl-36316274
ABSTRACT
A simple, highly sensitive and specific method based on high-performance liquid chromatography (HPLC) with ultraviolet detection was developed for the measurement of venetoclax concentrations in plasma samples. The chromatographic method employed a mobile phase of acetonitrile 0.5% KH2PO4 (pH 3.5) (80/20, v/v) on a CAPCELL PAK C18 UG120 column at a flow rate of 0.5 mL/min. The quantitative method was validated based on standards described in "Bioanalytical Method Validation Guidance for Industry" published by the US Food and Drug Administration. The separation of venetoclax and the internal standard R051012 was satisfactory, and the chromatograms were free of interfering peaks from the biological matrix. The intra- and inter-day coefficients of variation for venetoclax assays were <12.9%, whereas intra- and inter-day accuracies were within 13.6%. Only 100 µL of human plasma was required to detect a lower limit of quantification of 10 ng/mL for venetoclax. The recoveries of venetoclax extracted with an Oasis HLB cartridge were between 81 and 85%. The developed HPLC method was successfully applied to the determination of venetoclax concentrations in plasma of acute myeloid leukemia patients taking venetoclax. The degree of drug interactions between venetoclax and CYP3A4 inhibitors can be determined by this HPLC assay.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Chromatogr Sci Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Chromatogr Sci Año: 2022 Tipo del documento: Article País de afiliación: Japón