Your browser doesn't support javascript.
loading
Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement.
Damba, J; Pratt, Q; Hall-Chen, V H; Hong, R; Lantsov, R; Ellis, R; Rhodes, T L.
Afiliación
  • Damba J; Physics and Astronomy Department, UCLA, Los Angeles, California 90095, USA.
  • Pratt Q; Physics and Astronomy Department, UCLA, Los Angeles, California 90095, USA.
  • Hall-Chen VH; Institute of High Performance Computing, Singapore 138632.
  • Hong R; Physics and Astronomy Department, UCLA, Los Angeles, California 90095, USA.
  • Lantsov R; Physics and Astronomy Department, UCLA, Los Angeles, California 90095, USA.
  • Ellis R; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
  • Rhodes TL; Physics and Astronomy Department, UCLA, Los Angeles, California 90095, USA.
Rev Sci Instrum ; 93(10): 103549, 2022 Oct 01.
Article en En | MEDLINE | ID: mdl-36319338
ABSTRACT
The high density fluctuation poloidal wavenumber, kθ (kθ > 8 cm-1, kθρs > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k's. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher kθ (>8 cm-1) is substantially reduced, making it difficult to measure higher kθ turbulence. The new DBS system has been optimized to access higher wavenumber, kθ ≤ 20 cm-1, density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe's sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5-1.0. The new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2022 Tipo del documento: Article País de afiliación: Estados Unidos