Your browser doesn't support javascript.
loading
Time-resolved resonant soft X-ray scattering combined with MHz synchrotron X-ray and laser pulses at the Photon Factory.
Fukaya, Ryo; Adachi, Jun Ichi; Nakao, Hironori; Yamasaki, Yuichi; Tabata, Chihiro; Nozawa, Shunsuke; Ichiyanagi, Kouhei; Ishii, Yuta; Kimura, Hiroyuki; Adachi, Shin Ichi.
Afiliación
  • Fukaya R; Institute of Materials Structure Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki 305-0801, Japan.
  • Adachi JI; Institute of Materials Structure Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki 305-0801, Japan.
  • Nakao H; Institute of Materials Structure Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki 305-0801, Japan.
  • Yamasaki Y; Research and Services Division of Materials Data and Integrated System, National Institute for Materials Science, Tsukuba, Ibaraki 305-0044, Japan.
  • Tabata C; Institute for Integrated Radiation and Nuclear Science, Kyoto University, Kumatori, Osaka 590-0494, Japan.
  • Nozawa S; Institute of Materials Structure Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki 305-0801, Japan.
  • Ichiyanagi K; Institute of Materials Structure Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki 305-0801, Japan.
  • Ishii Y; Department of Physics, Tohoku University, Sendai, Miyagi 980-8578, Japan.
  • Kimura H; Department of Physics, Tohoku University, Sendai, Miyagi 980-8578, Japan.
  • Adachi SI; Institute of Materials Structure Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki 305-0801, Japan.
J Synchrotron Radiat ; 29(Pt 6): 1414-1419, 2022 Nov 01.
Article en En | MEDLINE | ID: mdl-36345749
ABSTRACT
A picosecond pump-probe resonant soft X-ray scattering measurement system has been developed at the Photon Factory storage ring for highly efficient data collection. A high-repetition-rate high-power compact laser system has been installed to improve efficiency via flexible data acquisition to a sub-MHz frequency in time-resolved experiments. Data are acquired by gating the signal of a channel electron multiplier with a pulse-counting mode capable of discriminating single-bunch soft X-ray pulses in the dark gap of the hybrid operation mode in the storage ring. The photoinduced dynamics of magnetic order for multiferroic manganite SmMn2O5 are clearly demonstrated by the detection of transient changes in the resonant soft X-ray scattering intensity around the Mn LIII- and O K-edges.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Synchrotron Radiat Asunto de la revista: RADIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Synchrotron Radiat Asunto de la revista: RADIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Japón