Your browser doesn't support javascript.
loading
Evaluation of Mitral-Aortic Flow Velocity Integral Ratio as a Tool to Differentiate Between Severe and Nonsevere Mitral Regurgitation.
Gogoi, Gaurav Kumar; Das, Soumi; Sen, Chaitali; Hazra, Avijit.
Afiliación
  • Gogoi GK; Department of Cardiac Anaesthesiology, I.P.G.M.E&R and S.S.K.M. Hospital, Kolkata, India.
  • Das S; Department of Cardiac Anaesthesiology, I.P.G.M.E&R and S.S.K.M. Hospital, Kolkata, India. Electronic address: soumidasanaesth79@gmail.com.
  • Sen C; Department of Cardiac Anaesthesiology, I.P.G.M.E&R and S.S.K.M. Hospital, Kolkata, India.
  • Hazra A; Department of Pharmacology, I.P.G.M.E&R and S.S.K.M. Hospital, Kolkata, India.
J Cardiothorac Vasc Anesth ; 37(1): 16-22, 2023 01.
Article en En | MEDLINE | ID: mdl-36357305
OBJECTIVES: To evaluate mitral-aortic flow velocity integral ratio (MAVIR) as an echocardiographic tool to differentiate between severe and nonsevere mitral regurgitation (MR), compared with regurgitant volume (RVol) and effective regurgitant orifice area (EROA), with subgroup analysis in patients with calcific mitral valve, both by transthoracic (TTE) and transesophageal (TEE) echocardiography. Also, whether MAVIR can be used as a screening tool for severe MR. DESIGN: Prospective, cross-sectional, observational. SETTING: Cardiac operating room of a tertiary-care hospital. PARTICIPANTS: One hundred adult patients with chronic mitral regurgitation with at least mild MR by two-dimensional Doppler and with absence of mitral stenosis, aortic valve disease, and rhythm other than sinus scheduled for cardiac surgery. The subgroup (n = 24) consisted specifically of patients with a calcific mitral valve. INTERVENTIONS: Preinduction TTE and postinduction TEE in the operating room. MEASUREMENTS AND RESULTS: MAVIR, RVol, and EROA were measured in all patients both by TTE and TEE. Cohen's kappa statistics was employed to quantify concordance among RVol, EROA, and MAVIR. Diagnostic indices of MAVIR toward diagnosis of severe MR also were quantified. The results showed a strong agreement, in differentiating severe from nonsevere MR, between MAVIR and both RVol and EROA in the whole cohort (n = 100) and the subgroup (n = 24), both by TTE and TEE. Diagnostic indices were high for MAVIR compared with RVol and EROA in detecting severe MR, both by TTE and TEE. CONCLUSION: MAVIR may be used as an echocardiographic tool to differentiate between severe and nonsevere MR, even in patients with calcific valves. It also can be used to screen patients for severe MR.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ecocardiografía Tridimensional / Insuficiencia de la Válvula Mitral Límite: Adult / Humans Idioma: En Revista: J Cardiothorac Vasc Anesth Asunto de la revista: ANESTESIOLOGIA / CARDIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: India Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ecocardiografía Tridimensional / Insuficiencia de la Válvula Mitral Límite: Adult / Humans Idioma: En Revista: J Cardiothorac Vasc Anesth Asunto de la revista: ANESTESIOLOGIA / CARDIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: India Pais de publicación: Estados Unidos