Reproducibility of T and T2 quantification in a multi-vendor multi-site study.
Lartey, R; Nanavati, A; Kim, J; Li, M; Xu, K; Nakamura, K; Shin, W; Winalski, C S; Obuchowski, N; Bahroos, E; Link, T M; Hardy, P A; Peng, Q; Kim, J; Liu, K; Fung, M; Wu, C; Li, X.
Afiliación
  • Lartey R; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, OH, USA.
  • Nanavati A; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, OH, USA.
  • Kim J; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, OH, USA.
  • Li M; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, OH, USA.
  • Xu K; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, OH, USA.
  • Nakamura K; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, OH, USA.
  • Shin W; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, OH, USA.
  • Winalski CS; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, OH, USA; Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, OH, USA.
  • Obuchowski N; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Quantitative Health Sciences, Lerner Research Institute, Cleveland Clinic, OH, USA.
  • Bahroos E; Department of Radiology and Biomedical Imaging, University of California, San Francisco (UCSF), CA, USA.
  • Link TM; Department of Radiology and Biomedical Imaging, University of California, San Francisco (UCSF), CA, USA.
  • Hardy PA; Department of Radiology, University of Kentucky, Lexington KY, USA.
  • Peng Q; Department of Radiology, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, NY, USA.
  • Kim J; Arthritis Foundation, GA, USA.
  • Liu K; Siemens Medical Solution Inc., USA.
  • Fung M; GE Healthcare, Waukesha, WI, USA.
  • Wu C; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Li X; Program of Advanced Musculoskeletal Imaging (PAMI), Cleveland Clinic, OH, USA; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, OH, USA; Department of Diagnostic Radiology, Imaging Institute, Cleveland Clinic, OH, USA. Electronic address: lix6@ccf.org.
Osteoarthritis Cartilage ; 31(2): 249-257, 2023 02.
Article en En | MEDLINE | ID: mdl-36370959
ABSTRACT

OBJECTIVE:

To evaluate the multi-vendor multi-site reproducibility of two-dimensional (2D) multi-echo spin-echo (MESE) T2 mapping (product sequences); and to evaluate the longitudinal reproducibility of three-dimensional (3D) magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (MAPSS) T1ρ and T2 mapping (research sequences), and 2D MESE T2 mapping, separated by 6 months, in a multi-vendor multi-site setting.

METHODS:

Phantoms and volunteers (n = 5 from each site, n = 20 in total) were scanned on four 3 T magnetic resonance (MR) systems from four sites and three vendors (Siemens, General Electric, and Phillips). Two traveling volunteers (3 knees) scanned at all 4 sites at baseline and 6-month follow-up. Data was transferred to one site for centralized processing. Coefficients of variation (CVs) were calculated to evaluate reproducibility.

RESULTS:

For baseline 2D MESE T2 measures, average CV were 0.37-2.45% (intra-site) and 5.96% (inter-site) for phantoms, and 3.15-8.49% (intra-site) and 14.16% (inter-site) for volunteers. For longitudinal phantom data, intra-site CVs were 1.42-3.48% for 3D MAPSS T1ρ, 1.77-3.56% for 3D MAPSS T2, and 1.02-2.54% for 2D MESE T2. For the longitudinal volunteer data, the intra-site CVs were 2.60-4.86% for 3D MAPSS T1ρ, 3.33-7.25% for 3D MAPSS T2, and 3.11-8.77% for 2D MESE T2.

CONCLUSION:

This study demonstrated excellent intra-site reproducibility of 2D MESE T2 imaging, while its inter-site variation was slightly higher than 3D MAPSS T2 imaging (10.06% as previously reported). This study also showed excellent reproducibility of longitudinal T1ρ and T2 cartilage quantification, in a multi-vendor multi-site setting for both product 2D MESE T2 and 3D MAPSS T1p/T2 research sequences.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Cartílago Articular Límite: Humans Idioma: En Revista: Osteoarthritis Cartilage Asunto de la revista: ORTOPEDIA / REUMATOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Cartílago Articular Límite: Humans Idioma: En Revista: Osteoarthritis Cartilage Asunto de la revista: ORTOPEDIA / REUMATOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos