Your browser doesn't support javascript.
loading
Evaluation of the quantitative performance of non-enhanced dual-energy CT X-map in detecting acute ischemic brain stroke: A model observer study using computer simulation.
Itoh, Toshihide; Noguchi, Kyo.
Afiliación
  • Itoh T; Department of CT Research and Collaboration, Siemens Healthineers, 1-11-1 Osaki, Shinagawa, Tokyo 141-8644, Japan. Electronic address: toshihide.itoh@siemens-healthineers.com.
  • Noguchi K; Department of Radiology, Graduate School of Medicine and Pharmaceutical Science, University of Toyama, 2630 Sugitani, Toyama city, Toyama 930-0194, Japan.
Phys Med ; 104: 85-92, 2022 Dec.
Article en En | MEDLINE | ID: mdl-36371946
PURPOSE: A simulation study was performed to evaluate the quantitative performance of X-map images-derived from non-enhanced (NE) dual-energy computed tomography (DECT)-in detecting acute ischemic stroke (AIS) compared with that of NE-DECT mixed images. METHODS: A virtual phantom, 150 mm in diameter, filled with tissues comprising various gray- and white-matter proportions was used to generate pairs of NE-head images at 80 kV and Sn150 kV at three dose levels (20, 40, and 60 mGy). The phantom included an inserted low-contrast object, 15 mm in diameter, with four densities (0%, 5%, 10%, and 15%) mimicking ischemic edema. Mixed and X-map images were generated from these sets of images and compared in terms of detectability of ischemic edema using a channelized Hotelling observer (CHO). The area under the curve (AUC) of the receiver operating characteristic that generated CHO for each condition was used as a figure of merit. RESULTS: The AUCs of X-map images were always significantly higher than those of mixed images (P < 0.001). The improvement in AUC for X-map images compared with that for mixed images at edema densities was 9.2%-12.6% at 20 mGy, 10.1%-17.7% at 40 mGy, and 14.0%-19.4% at 60 mGy. At any edema density, X-map images at 20 mGy resulted in higher AUCs than mixed images acquired at any other dose level (P < 0.001), which corresponded to a 66% dose reduction on X-map images. CONCLUSIONS: The simulation study confirmed that NE-DECT X-map images have superior capability of detecting AIS than NE-DECT mixed images.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Accidente Cerebrovascular Isquémico Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2022 Tipo del documento: Article Pais de publicación: Italia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Accidente Cerebrovascular Isquémico Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Phys Med Asunto de la revista: BIOFISICA / BIOLOGIA / MEDICINA Año: 2022 Tipo del documento: Article Pais de publicación: Italia