Functional implant positioning in total hip arthroplasty and the role of robotic-arm assistance.
Fontalis, Andreas; Raj, Rhody David; Kim, Woo Jae; Gabr, Ayman; Glod, Fabrice; Foissey, Constant; Kayani, Babar; Putzeys, Pierre; Haddad, Fares S.
Afiliación
  • Fontalis A; Department of Trauma and Orthopaedic Surgery, University College Hospital, London, UK. andreasfontalis@gmail.com.
  • Raj RD; Division of Surgery and Interventional Science, University College London, Gower Street, London, WC1E 6BT, UK. andreasfontalis@gmail.com.
  • Kim WJ; Department of Trauma and Orthopaedic Surgery, University College Hospital, London, UK.
  • Gabr A; Department of Trauma and Orthopaedic Surgery, University College Hospital, London, UK.
  • Glod F; Department of Trauma and Orthopaedic Surgery, University College Hospital, London, UK.
  • Foissey C; Hôpitaux Robert Schuman, Luxembourg City, Luxembourg.
  • Kayani B; Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, Lyon, France.
  • Putzeys P; Department of Trauma and Orthopaedic Surgery, University College Hospital, London, UK.
  • Haddad FS; Hôpitaux Robert Schuman, Luxembourg City, Luxembourg.
Int Orthop ; 47(2): 573-584, 2023 02.
Article en En | MEDLINE | ID: mdl-36496548
INTRODUCTION: Accurate implant positioning, tailored to the phenotype and unique biomechanics of each patient is the single most important objective in achieving stability in THA and maximise range of motion. The spine-pelvis-hip construct functions as a single unit adapting to postural changes. It is widely accepted in the literature that no universaltarget exists and variations in spinopelvic mobility mandate adjustments to the surgical plan; thus bringing to the fore the concept of personalised, functional component positioning. METHODS: This manuscript aims to outline the challenges posed by spinopelvic imbalance and present a reproducible, stepwise approach to achieve functional-component positioning. We also present the one-year functional outcomes and Patient Reported Outcome Measures of a prospective cohort operated with this technique. RESULTS AND CONCLUSION: Robotic-arm assisted Total Hip Arthroplasty has facilitated enhanced planning based on the patient's phenotype and evidence suggests it results in more reproducible and accurate implant positioning. Preservation of offset, avoiding leg-length discrepancy, accurate restoration of the centre of rotation and accomplishing the combinedversion target are very important parameters in Total Hip Arthroplasty that affect post-operative implant longevity, patient satisfaction and clinical outcomes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Procedimientos Quirúrgicos Robotizados Aspecto: Patient_preference Idioma: En Revista: Int Orthop Año: 2023 Tipo del documento: Article Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Procedimientos Quirúrgicos Robotizados Aspecto: Patient_preference Idioma: En Revista: Int Orthop Año: 2023 Tipo del documento: Article Pais de publicación: Alemania