Your browser doesn't support javascript.
loading
Unattended versus Attended Blood Pressure Measurement: Relationship with Retinal Microcirculation.
Paini, Anna; Agabiti Rosei, Claudia; De Ciuceis, Carolina; Aggiusti, Carlo; Bertacchini, Fabio; Cacciatore, Marco; Capellini, Sara; Gatta, Roberto; Malerba, Paolo; Stassaldi, Deborah; Rizzoni, Damiano; Salvetti, Massimo; Muiesan, Maria Lorenza.
Afiliación
  • Paini A; Department of Clinical and Experimental Sciences, University of Brescia & Emergency Medicine ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Agabiti Rosei C; Department of Clinical and Experimental Sciences, University of Brescia & 2a Medicina ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • De Ciuceis C; Department of Clinical and Experimental Sciences, University of Brescia & Emergency Medicine ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Aggiusti C; Department of Clinical and Experimental Sciences, University of Brescia & Emergency Medicine ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Bertacchini F; Department of Clinical and Experimental Sciences, University of Brescia & 2a Medicina ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Cacciatore M; Department of Clinical and Experimental Sciences, University of Brescia & 2a Medicina ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Capellini S; Department of Clinical and Experimental Sciences, University of Brescia & 2a Medicina ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Gatta R; Department of Clinical and Experimental Sciences, University of Brescia, 25123 Brescia, Italy.
  • Malerba P; Department of Clinical and Experimental Sciences, University of Brescia & 2a Medicina ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Stassaldi D; Department of Clinical and Experimental Sciences, University of Brescia & 2a Medicina ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Rizzoni D; Department of Clinical and Experimental Sciences, University of Brescia & Medicina Montichiari ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Salvetti M; Department of Clinical and Experimental Sciences, University of Brescia & Emergency Medicine ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
  • Muiesan ML; Department of Clinical and Experimental Sciences, University of Brescia & 2a Medicina ASST Spedali Civili di Brescia, 25121 Brescia, Italy.
J Clin Med ; 11(23)2022 Nov 25.
Article en En | MEDLINE | ID: mdl-36498540
Though the relationship between both "attended" and "unattended" BP and several forms of target organ damage have been evaluated, data on retinal arteriolar alterations are lacking. The aim of our study was to evaluate the relationship between "attended" or "unattended" BP values and retinal arteriolar changes in consecutive individuals undergoing a clinical evaluation and assessment of retinal fundus at an ESH Excellence Centre. An oscillometric device programmed to perform 3 BP measurements, at 1 min intervals and after 5 min of rest was used on all individuals to measure BP with the patient alone in the room ("unattended") or in the presence of the physician ("attended") in the same day in a random order. The retinal arteriole's wall thickness (WT) was measured automatically by a localization algorithm as the difference between external (ED) and internal diameter (ID) by adaptive optics (RTX-1, Imagine Eyes, Orsay, Francia). Media-to-lumen ratio (WLR) of the retinal arterioles and cross-sectional area (WCSA) of the vascular wall were calculated. Results: One-hundred-forty-two patients were examined (mean age 57 ± 12 yrs, 48% female, mean BMI 26 ± 4). Among them, 60% had hypertension (84% treated) and 11% had type 2 diabetes mellitus. Unattended systolic BP (SBP) was lower as compared to attended SBP (129 ± 14.8. vs. 122.1 ± 13.6 mmHg, p < 0.0001). WLR was similarly correlated with unattended and attended SBP (r = 0.281, p < 0.0001 and r = 0.382, p < 0.0001) and with unattended and attended diastolic BP (r = 0.34, p < 0.001 and r = 0.29, p < 0.0001). The differences between correlations were not statistically significant (Steiger's Z test). Conclusion: The measurement of "unattended" or "attended" BP provides different values, and unattended BP is lower as compared to attended BP. In this study a similar correlation was observed between attended and unattended BP values and structural changes of retinal arterioles.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2022 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2022 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Suiza