Your browser doesn't support javascript.
loading
Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry.
Wu, Yanxiang; Wang, Songxue; Cui, Weibing; Tian, Wei; Zhang, Jieqiong; Chen, Xi; Zhou, Minghui.
Afiliación
  • Wu Y; The Academy of National Food and Strategic Reserves Administration, Beijing 100037, China.
  • Wang S; The Academy of National Food and Strategic Reserves Administration, Beijing 100037, China.
  • Cui W; Beijing Purkinje General Instrument Co., Ltd., Beijing 101299, China.
  • Tian W; The Academy of National Food and Strategic Reserves Administration, Beijing 100037, China.
  • Zhang J; The Academy of National Food and Strategic Reserves Administration, Beijing 100037, China.
  • Chen X; The Academy of National Food and Strategic Reserves Administration, Beijing 100037, China.
  • Zhou M; The Academy of National Food and Strategic Reserves Administration, Beijing 100037, China.
Molecules ; 27(23)2022 Dec 05.
Article en En | MEDLINE | ID: mdl-36500663
ABSTRACT
A simple, rapid, sensitive, accurate, and automatic graphite furnace atomic absorption spectrometry (GFAAS) method for detecting Cd and Pb in cereals is presented. This method enables the simultaneous determination of Cd and Pb in cereals with a pre-treatment method of diluted acid extraction and a high-performance lead-cadmium composite hollow-cathode lamp (LCC-HCL), and it realizes automatic determination from sample weighing to result output through an automatic diluted acid extraction system. Under the optimization, Pb and Cd in cereals were simultaneously and automatically detected in up to 240 measurements in 8 h. The LOD and LOQ of this method were 0.012 and 0.040 mg·kg-1 for Pb, and 0.0014 and 0.0047 mg·kg-1 for Cd, respectively. The results of the four certified reference materials were satisfied; there was no significant difference compared with the ICP-MS method according to a t-test, and the RSDs were less than 5% for Cd and Pb. The recoveries of naturally contaminated samples compared with the ICP-MS method were favorable, with 80-110% in eight laboratories. The developed method is rapid, low-cost, and highly automated and may be a good choice for grain quality discrimination and rapid analysis of Cd and Pb in different institutions.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cadmio / Grafito Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cadmio / Grafito Idioma: En Revista: Molecules Asunto de la revista: BIOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: China