Radiobiological and dosimetric comparison of 60Co versus 192Ir high-dose-rate intracavitary-interstitial brachytherapy for cervical cancer.
Radiat Oncol
; 17(1): 206, 2022 Dec 13.
Article
en En
| MEDLINE
| ID: mdl-36514118
BACKGROUND: High-dose-rate (HDR) intracavitary-interstitial brachytherapy (IC-ISBT) is an effective treatment for bulky, middle, and advanced cervical cancer. In this study, we compared the differences between 60Co and 192Ir HDR IC-ISBT plans in terms of radiobiological and dosimetric parameters, providing a reference for clinical workers in brachytherapy. METHODS: A total of 30 patients with cervical cancer receiving HDR IC-ISBT were included in this study, and IC-ISBT plans for each individual were designed with both 60Co and 192Ir at a prescribed dose of CTV D90 = 6 Gy while keeping the dose to OARs as low as possible. Physical dose and dose-volume parameters of CTV and OARs were extracted from TPS. The EQD2, EUBED, EUD, TCP, and NTCP were calculated using corresponding formulas. The differences between the 60Co and 192Ir IC-ISBT plans were compared using the paired t-test. RESULTS: In each patient's 60Co and 192Ir IC-ISBT plan, the average physical dose and EQD2 of 60Co were lower than those of 192Ir, and there were statistically significant differences in D2cc and D1cc for the OARs (p < 0.05); there were statistically significant differences in D0.1 cc for the bladder (p < 0.05) and no significant differences in D0.1 cc for the rectum or intestines (p > 0.05). The EUBED ratio (60Co/192Ir) at the CTV was mostly close to 1 when neither 60Co or 192Ir passed their half-lives or when both passed two half-lives, and the difference between them was not significant; at the OARs, the mean value of 60Co was lower than that of 192Ir. There was no statistical difference between 60Co and 192Ir in the EUD (93.93 versus 93.92 Gy, p > 0.05) and TCP (97.07% versus 97.08%, p > 0.05) of the tumors. The mean NTCP value of 60Co was lower than that of 192Ir. CONCLUSIONS: Considering the CTV and OARs, the dosimetric parameters of 60Co and 192Ir are comparable. Compared with 192Ir, the use of 60Co for HDR IC-ISBT can ensure a similar tumor control probability while providing better protection to the OARs. In addition, 60Co has obvious economic advantages and can be promoted as a good alternative to 192Ir.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Braquiterapia
/
Neoplasias del Cuello Uterino
Tipo de estudio:
Etiology_studies
Límite:
Female
/
Humans
Idioma:
En
Revista:
Radiat Oncol
Asunto de la revista:
NEOPLASIAS
/
RADIOTERAPIA
Año:
2022
Tipo del documento:
Article
País de afiliación:
China
Pais de publicación:
Reino Unido