OTOPLAN-Based Study of Intracochlear Electrode Position Through Cochleostomy and Round Window in Transcanal Veria Technique.
Bhavana, Kranti; Timmaraju, Sailaja; Kumar, Vijay; Kumar, Chandan; Bharti, Bhartendu; Prakash, Rudra; Sinha, Upasana.
Afiliación
  • Bhavana K; Department of Otorhinolaryngology, AIIMS Patna, Phulwarisharif, Patna, 801507 India.
  • Timmaraju S; Education and Training, MED-EL India, New Delhi, India.
  • Kumar V; Department of Otorhinolaryngology, AIIMS Patna, Phulwarisharif, Patna, 801507 India.
  • Kumar C; Speech and Hearing Care Pvt Ltd, Patna, India.
  • Bharti B; Department of Otorhinolaryngology, AIIMS Patna, Phulwarisharif, Patna, 801507 India.
  • Prakash R; Department of Otorhinolaryngology, AIIMS Patna, Phulwarisharif, Patna, 801507 India.
  • Sinha U; Department of Radiodiagnosis, AIIMS Patna, Patna, India.
Indian J Otolaryngol Head Neck Surg ; 74(4): 575-581, 2022 Dec.
Article en En | MEDLINE | ID: mdl-36514425
ABSTRACT
To study the postoperative visualisation of the electrode array insertion angle through transcanal Veria approach in both round window and cochleostomy techniques. Retrospective study. Tertiary care centre. 26 subjects aged 2-15 years implanted with a MED-EL STANDARD electrode array (31.5 mm) through Veria technique were selected. 16 had the electrode insertion through the round window, 10 through anteroinferior cochleostomy. DICOM files of postoperative computer tomography (CT) scans were collected and analysed using the OTOPLAN 3.0 software. Examined parameters were cochlear duct length, average angle of insertion depth. Pearson's Correlation Test was utilized for statistical analysis. Average cochlear duct length was 38.12 mm, ranging from 34.2 to 43 mm. Average angle of insertion depth was 666 degrees through round window insertion and 670 degrees through cochleostomy insertion. Pearson's correlation showed no significant difference in average angle of insertion depth between subjects with cochleostomy and round window insertion. Detailed study on the OTOPLAN software has established that there remains no difference between round window insertion or cochleostomy insertion when it comes to electrode array position and placement in the scala tympani. It is feasible to perform round window insertion and cochleostomy insertion through transcanal Veria approach as this technique provides good visualisation. Supplementary Information The online version contains supplementary material available at 10.1007/s12070-022-03228-5.