Your browser doesn't support javascript.
loading
Motion Compensation for 3D Multispectral Handheld Photoacoustic Imaging.
Yoon, Chiho; Lee, Changyeop; Shin, Keecheol; Kim, Chulhong.
Afiliación
  • Yoon C; Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
  • Lee C; Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
  • Shin K; LIG Nex1, Yongin-si 13488, Republic of Korea.
  • Kim C; Departments of Electrical Engineering, Convergence IT Engineering, and Mechanical Engineering, Medical Science and Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.
Biosensors (Basel) ; 12(12)2022 Nov 29.
Article en En | MEDLINE | ID: mdl-36551059
ABSTRACT
Three-dimensional (3D) handheld photoacoustic (PA) and ultrasound (US) imaging performed using mechanical scanning are more useful than conventional 2D PA/US imaging for obtaining local volumetric information and reducing operator dependence. In particular, 3D multispectral PA imaging can capture vital functional information, such as hemoglobin concentrations and hemoglobin oxygen saturation (sO2), of epidermal, hemorrhagic, ischemic, and cancerous diseases. However, the accuracy of PA morphology and physiological parameters is hampered by motion artifacts during image acquisition. The aim of this paper is to apply appropriate correction to remove the effect of such motion artifacts. We propose a new motion compensation method that corrects PA images in both axial and lateral directions based on structural US information. 3D PA/US imaging experiments are performed on a tissue-mimicking phantom and a human wrist to verify the effects of the proposed motion compensation mechanism and the consequent spectral unmixing results. The structural motions and sO2 values are confirmed to be successfully corrected by comparing the motion-compensated images with the original images. The proposed method is expected to be useful in various clinical PA imaging applications (e.g., breast cancer, thyroid cancer, and carotid artery disease) that are susceptible to motion contamination during multispectral PA image analysis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Fotoacústicas Límite: Humans Idioma: En Revista: Biosensors (Basel) Año: 2022 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Técnicas Fotoacústicas Límite: Humans Idioma: En Revista: Biosensors (Basel) Año: 2022 Tipo del documento: Article