In vitro comparison of the color degradation of two computer-aided design/computer-aided manufacturing provisional materials: A 12-month simulation.
Sayegh, Suzanna Maria; Daou, Maha; Najjar, Georges; Zebouni, Elie.
Afiliación
  • Sayegh SM; Department of Prosthodontics, Saint Joseph University of Beirut, Beirut, Lebanon.
  • Daou M; Department of Pediatrics, McGill University, Saint Joseph University of Beirut, Beirut, Lebanon.
  • Najjar G; Department of Prosthodontics, Saint Joseph University of Beirut, Beirut, Lebanon.
  • Zebouni E; Department of Prosthodontics, Saint Joseph University of Beirut, Beirut, Lebanon.
J Indian Prosthodont Soc ; 23(1): 38-44, 2023.
Article en En | MEDLINE | ID: mdl-36588373
ABSTRACT

Aim:

This study evaluated the color aging of two computer aided design/computer aided manufacturing (CAD/CAM) provisional materials of different compositions (polymethyl methacrylate and composite resin) after exposure to thermal aging and immersion in coffee for 3, 6, and 12 intraoral months. Setting and

Design:

The current in vitro study was conducted from September to December 2021 at the Craniofacial laboratory at the Saint Joseph University in Beirut, Lebanon. Materials and

Methods:

The shades of 2.0 mm thick, 10.0 mm in diameter disk shaped specimens of VITA CAD Temp® and Ceramill® TEMP were measured using the VITA Linearguide 3D MASTER® and a conversion table to extract the CIE LFNx01aFNx01bFNx01 values on a white background (n = 30). Statistical Analysis Used The color differences ΔE at 3, 6, and 12 months were calculated and analyzed by repeated measures ANOVA followed by Bonferroni multiple comparisons, univariate analyses, and one sample t tests.

Results:

The mean ΔET1/T0, ΔET2/T0, and ΔET3/T0 values were significantly higher than the cutoff values for acceptability and perceptibility for the VITA CAD Temp® and the Ceramill® TEMP groups. In addition, the increase in ΔE overtime was significantly greater in the Ceramill® TEMP group compared to the VITA CAD Temp® group.

Conclusions:

The Ceramill® TEMP changed color more and faster than the VITA CAD Temp®. In addition, whether at 3, 6, or 12 months, the color variations of both materials are not only perceptible but also unacceptable compared to the initial shade.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Polimetil Metacrilato / Porcelana Dental Límite: Humans Idioma: En Revista: J Indian Prosthodont Soc Año: 2023 Tipo del documento: Article País de afiliación: Líbano