Your browser doesn't support javascript.
loading
A Complete Pipeline for Untargeted Urinary Volatolomic Profiling with Sorptive Extraction and Dual Polar and Nonpolar Column Methodologies Coupled with Gas Chromatography Time-of-Flight Mass Spectrometry.
Wen, Qing; Myridakis, Antonis; Boshier, Piers R; Zuffa, Simone; Belluomo, Ilaria; Parker, Aaron G; Chin, Sung-Tong; Hakim, Stephanie; Markar, Sheraz R; Hanna, George B.
Afiliación
  • Wen Q; Department of Surgery and Cancer, Imperial College London, London W12 0HS, United Kingdom.
  • Myridakis A; Department of Surgery and Cancer, Imperial College London, London W12 0HS, United Kingdom.
  • Boshier PR; Department of Surgery and Cancer, Imperial College London, London W12 0HS, United Kingdom.
  • Zuffa S; Department of Metabolism, Digestion and Reproduction, Imperial College London, London SW7 2AZ, United Kingdom.
  • Belluomo I; Department of Surgery and Cancer, Imperial College London, London W12 0HS, United Kingdom.
  • Parker AG; Department of Surgery and Cancer, Imperial College London, London W12 0HS, United Kingdom.
  • Chin ST; Department of Surgery and Cancer, Imperial College London, London W12 0HS, United Kingdom.
  • Hakim S; Department of Surgery and Cancer, Imperial College London, London W12 0HS, United Kingdom.
  • Markar SR; Department of Surgery and Cancer, Imperial College London, London W12 0HS, United Kingdom.
  • Hanna GB; Nuffield Department of Surgical Sciences, University of Oxford, Oxford OX3 9DU, United Kingdom.
Anal Chem ; 95(2): 758-765, 2023 01 17.
Article en En | MEDLINE | ID: mdl-36602225
ABSTRACT
Volatolomics offers an opportunity for noninvasive detection and monitoring of human disease. While gas chromatography-mass spectrometry (GC-MS) remains the technique of choice for analyzing volatile organic compounds (VOCs), barriers to wider adoption in clinical practice still exist, including sample preparation and introduction techniques, VOC extraction, throughput, volatolome coverage, biological interpretation, and quality control (QC). Therefore, we developed a complete pipeline for untargeted urinary volatolomic profiling. We optimized a novel extraction technique using HiSorb sorptive extraction, which exhibited high analytical performance and throughput. We achieved a broader VOC coverage by using HiSorb coupled with a set of complementary chromatographic methods and time-of-flight mass spectrometry. Furthermore, we developed a data preprocessing strategy by evaluating internal standard normalization, batch correction, and we adopted strict QC measures including removal of nonlinearly responding, irreproducible, or contaminated metabolic features, ensuring the acquisition of high-quality data. The applicability of this pipeline was evaluated in a clinical cohort consisting of pancreatic ductal adenocarcinoma (PDAC) patients (n = 28) and controls (n = 33), identifying four urinary candidate biomarkers (2-pentanone, hexanal, 3-hexanone, and p-cymene), which can successfully discriminate the cancer and noncancer subjects. This study presents an optimized, high-throughput, and quality-controlled pipeline for untargeted urinary volatolomic profiling. Use of the pipeline to discriminate PDAC from control subjects provides proof of principal of its clinical utility and potential for application in future biomarker discovery studies.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Compuestos Orgánicos Volátiles Límite: Humans Idioma: En Revista: Anal Chem Año: 2023 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Compuestos Orgánicos Volátiles Límite: Humans Idioma: En Revista: Anal Chem Año: 2023 Tipo del documento: Article País de afiliación: Reino Unido