Utility of the BioFire® FilmArray® Pneumonia Panel plus assay for syndromic testing of lower respiratory tract infections in a low/middle-income setting.
Van Der Westhuyzen, M; Samodien, N; Brink, A J; Moodley, C.
Afiliación
  • Van Der Westhuyzen M; Division of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa.
  • Samodien N; National Health Laboratory Service, Microbiology, Groote Schuur Hospital, Cape Town, South Africa.
  • Brink AJ; Division of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa.
  • Moodley C; National Health Laboratory Service, Microbiology, Groote Schuur Hospital, Cape Town, South Africa.
JAC Antimicrob Resist ; 5(1): dlac139, 2023 Feb.
Article en En | MEDLINE | ID: mdl-36628341
ABSTRACT

Background:

Determining lower respiratory tract infection (LRTI) aetiology is complex. Culture-based methods are laborious with poor sensitivity. Molecular assays improve detection of potential pathogens, but incorrect interpretation of results may lead to inappropriate antimicrobial therapy.

Methods:

The utility of the BioFire® FilmArray® Pneumonia Panel plus (FA-PP) to detect LRTI pathogens, and the potential impact on antimicrobial stewardship in a low-resource setting, were assessed. Routine LRT samples were included from adult patients with clinically suspected LRTI or with a concomitant blood culture at Groote Schuur Hospital and referring facilities. Culture and FA-PP results were compared, and pharmacy data analysed to determine appropriateness of antibiotic therapy.

Results:

There was an 80% correlation between cultured LRTI pathogens and the FA-PP bin ≥107 results. Compared with culture, the FA-PP detected substantially more pathogens (86.6% versus 17.9%) and produced a combined 100% positive percent agreement, and 88% negative percent agreement. The FA-PP detected bacterial/viral coinfections in 27% of samples. Correlation of FA-PP results with pharmacy data (n = 69) indicated a potential antibiotic change in 75% of cases, but this is difficult to accurately characterize without a 'gold standard' for treatment or complete clinical data.

Conclusions:

The FA-PP increased the number of positive samples with typical bacteria, but the semi-quantitative reporting algorithm does not describe the correlation between the different bin values and colonization versus infection. This complicates result interpretation and may lead to inappropriate antimicrobial treatment. This study highlights the potential positive impact of rapid molecular assays for routine care in lower-income settings, but also underscores the interpretive challenges associated with these tests.