Your browser doesn't support javascript.
loading
Aptamer-linked photonic crystal hydrogel sensor for rapid point-of-care detection of human immuno-deficiency virus-1 (HIV-1).
Rizvi, Aysha Sarfraz; Murtaza, Ghulam; Zhang, Wenxin; Xue, Min; Qiu, Lili; Meng, Zihui.
Afiliación
  • Rizvi AS; School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China.
  • Murtaza G; School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China. Electronic address: murtaza1405@gmail.com.
  • Zhang W; School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China.
  • Xue M; School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China.
  • Qiu L; School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China.
  • Meng Z; School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China. Electronic address: mengzh@bit.edu.cn.
J Pharm Biomed Anal ; 227: 115104, 2023 Apr 01.
Article en En | MEDLINE | ID: mdl-36827736
ABSTRACT
The detection of the human immunodeficiency virus-1 (HIV) at an early stage is vital and could be realized through its cell surface glycoprotein-120 (gp120) without virus preprocessing. Here, we present an ssDNA-aptamer-linked photonic crystal (APC) hydrogel sensor for HIV detection which is comprised of photonic crystals (PCs) made of polystyrene nanoparticles embedded in the polyacrylamide hydrogel. ssDNA aptamers specific for gp120 are crosslinked in the hydrogel which can selectively bind to gp120 by hydrogen bonding increasing the PCs particle spacing and swelling of the hydrogel. The binding response can be visually monitored as a color change due to the diffraction of light from PCs and can eventually be measured (1-1000 ng mL-1 of gp120) and 100 to 108 VP mL-1 of HIV by the Debye's ring diameter or a UV/Vis spectrometer. APC-hydrogel can be regenerated by Tris-HCl and EDTA washing buffer system. The sensor demonstrates LOD of 7.1 ±â€¯1.55 ng mL-1 for gp120 and 4 VP mL-1 for the whole HIV, a rapid response of 5 min, reusability up to 70 % (in fifth use), and recovery of 95.4 ±â€¯0.1 % to 99.0 ±â€¯0.2 % in plasma samples. The sensor is cost-effect and stable compared to antibody-based sensors and can be utilized to develop point-of-care testing (POCT) devices for HIV diagnosis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones por VIH / VIH-1 Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Pharm Biomed Anal Año: 2023 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones por VIH / VIH-1 Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Pharm Biomed Anal Año: 2023 Tipo del documento: Article País de afiliación: China