Your browser doesn't support javascript.
loading
Green fluorometric strategy for simultaneous determination of the antihypertensive drug telmisartan (A tentative therapeutic for COVID-19) with Nebivolol in human plasma.
Salim, Mohamed M; Radwan, Aya Saad; Hadad, Ghada M; Belal, Fathalla; Elkhoudary, Mahmoud M.
Afiliación
  • Salim MM; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt. mmasalim@mans.edu.eg.
  • Radwan AS; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Horus University- Egypt, New Damietta, Egypt. mmasalim@mans.edu.eg.
  • Hadad GM; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Horus University- Egypt, New Damietta, Egypt.
  • Belal F; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt.
  • Elkhoudary MM; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt.
Sci Rep ; 13(1): 3576, 2023 03 02.
Article en En | MEDLINE | ID: mdl-36864220
ABSTRACT
Telmisartan (TEL) and Nebivolol (NEB) are frequently co-formulated in a single dosage form that is frequently prescribed for the treatment of hypertension, moreover, telmisartan is currently proposed to be used to treat COVID19-induced lung inflammation. Green rapid, simple, and sensitive synchronous spectrofluorimetric techniques for simultaneous estimation of TEL and NEB in their co-formulated pharmaceutical preparations and human plasma were developed and validated. Synchronous fluorescence intensity at 335 nm was used for TEL determination (Method I). For the mixture, the first derivative synchronous peak amplitudes (D1) at 296.3 and 320.5 nm were used for simultaneous estimation of NEB and TEL, respectively (Method II). The calibration plots were rectilinear over the concentration ranges of 30-550 ng/mL, and 50-800 ng/mL for NEB and TEL, respectively. The high sensitivity of the developed methods allowed for their analysis in human plasma samples. NEB`s Quantum yield was estimated by applying the single-point method. The greenness of the proposed approaches was evaluated using the Eco-scale, National Environmental Method Index (NEMI), and Green Analytical Procedure Index (GAPI) methods.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: COVID-19 / Antihipertensivos Límite: Humans Idioma: En Revista: Sci Rep Año: 2023 Tipo del documento: Article País de afiliación: Egipto

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: COVID-19 / Antihipertensivos Límite: Humans Idioma: En Revista: Sci Rep Año: 2023 Tipo del documento: Article País de afiliación: Egipto