Your browser doesn't support javascript.
loading
ABSTRACT

Background:

The performance of rapid antigen tests for SARS-CoV-2 (Ag-RDT) in temporal relation to symptom onset or exposure is unknown, as is the impact of vaccination on this relationship.

Objective:

To evaluate the performance of Ag-RDT compared with RT-PCR based on day after symptom onset or exposure in order to decide on 'when to test'. Design Setting and

Participants:

The Test Us at Home study was a longitudinal cohort study that enrolled participants over 2 years old across the United States between October 18, 2021 and February 4, 2022. All participants were asked to conduct Ag-RDT and RT-PCR testing every 48 hours over a 15-day period. Participants with one or more symptoms during the study period were included in the Day Post Symptom Onset (DPSO) analyses, while those who reported a COVID-19 exposure were included in the Day Post Exposure (DPE) analysis. Exposure Participants were asked to self-report any symptoms or known exposures to SARS-CoV-2 every 48-hours, immediately prior to conducting Ag-RDT and RT-PCR testing. The first day a participant reported one or more symptoms was termed DPSO 0, and the day of exposure was DPE 0. Vaccination status was self-reported. Main Outcome and

Measures:

Results of Ag-RDT were self-reported (positive, negative, or invalid) and RT-PCR results were analyzed by a central laboratory. Percent positivity of SARS-CoV-2 and sensitivity of Ag-RDT and RT-PCR by DPSO and DPE were stratified by vaccination status and calculated with 95% confidence intervals.

Results:

A total of 7,361 participants enrolled in the study. Among them, 2,086 (28.3%) and 546 (7.4%) participants were eligible for the DPSO and DPE analyses, respectively. Unvaccinated participants were nearly twice as likely to test positive for SARS-CoV-2 than vaccinated participants in event of symptoms (PCR+ 27.6% vs 10.1%) or exposure (PCR+ 43.8% vs. 22.2%). The highest proportion of vaccinated and unvaccinated individuals tested positive on DPSO 2 and DPE 5-8. Performance of RT-PCR and Ag-RDT did not differ by vaccination status. Ag-RDT detected 78.0% (95% Confidence Interval 72.56-82.61) of PCR-confirmed infections by DPSO 4. For exposed participants, Ag-RDT detected 84.9% (95% CI 75.0-91.4) of PCR-confirmed infections by day five post-exposure (DPE 5). Conclusions and Relevance Performance of Ag-RDT and RT-PCR was highest on DPSO 0-2 and DPE 5 and did not differ by vaccination status. These data suggests that serial testing remains integral to enhancing the performance of Ag-RDT.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies Idioma: En Revista: MedRxiv Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies Idioma: En Revista: MedRxiv Año: 2023 Tipo del documento: Article