Reference Standard for Digital Infrared Thermography of the Surface Temperature of the Lower Limbs.
Zhang, Ho Yeol; Son, Seong; Yoo, Byung Rhae; Youk, Tae-Mi.
Afiliación
  • Zhang HY; Department of Neurosurgery, National Health Insurance Service Ilsan Hospital, Yonsei University College of Medicine, Ilsan 10444, Republic of Korea.
  • Son S; Department of Neurosurgery, Gil Medical Center, Gachon University College of Medicine, Incheon 21565, Republic of Korea.
  • Yoo BR; Department of Neurosurgery, Gil Medical Center, Gachon University College of Medicine, Incheon 21565, Republic of Korea.
  • Youk TM; Research Institute, National Health Insurance Service Ilsan Hospital, Yonsei University College of Medicine, Ilsan 10444, Republic of Korea.
Bioengineering (Basel) ; 10(3)2023 Feb 21.
Article en En | MEDLINE | ID: mdl-36978674
ABSTRACT
Digital infrared thermographic imaging (DITI) is a supplementary diagnostic technique to visualize the surface temperature of the human body. However, there is currently no reference standard for the lower limbs for accurate diagnosis. In this study, we performed DITI on the lower limbs of 905 healthy Korean volunteers (411 males and 494 females aged between 20 and 69 years) to obtain reference standard data. Thermography was conducted on the front, back, lateral sides, and sole area, and 188 regions of interest (ROIs) were analyzed. Additionally, subgroup analysis was conducted according to the proximity of ROIs, sex, and age groups. The mean temperatures of ROIs ranged from 24.60 ± 5.06 to 28.75 ± 5.76 °C and the absolute value of the temperature difference between both sides reached up to 1.06 ± 2.75 °C. According to subgroup analysis, the sole area had a significantly lower temperature than any other areas, men had higher temperatures than women, and the elderly had higher temperatures than the young adults except for the 20s age group (p < 0.001, respectively). This result could be used as a foundation for the establishment of a reference standard for DITI. Practical patient DITI can be accurately interpreted using these data, and it can serve as a basis for further scientific research.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Bioengineering (Basel) Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Bioengineering (Basel) Año: 2023 Tipo del documento: Article
...