Your browser doesn't support javascript.
loading
Effect of Different Vat Polymerization Techniques on Mechanical and Biological Properties of 3D-Printed Denture Base.
Lee, Hao-Ern; Alauddin, Muhammad Syafiq; Mohd Ghazali, Mohd Ifwat; Said, Zulfahmi; Mohamad Zol, Syazwani.
Afiliación
  • Lee HE; Faculty of Dentistry, Universiti Sains Islam Malaysia, Kuala Lumpur 56100, Malaysia.
  • Alauddin MS; Smart Manufacturing and Advanced Renewable Technology Research Group, Faculty Science and Technology, Universiti Sains Islam Malaysia, Nilai 71800, Malaysia.
  • Mohd Ghazali MI; Smart Manufacturing and Advanced Renewable Technology Research Group, Faculty Science and Technology, Universiti Sains Islam Malaysia, Nilai 71800, Malaysia.
  • Said Z; Department of Conservative Dentistry and Prosthodontics, Universiti Sains Islam Malaysia, Kuala Lumpur 56100, Malaysia.
  • Mohamad Zol S; Smart Manufacturing and Advanced Renewable Technology Research Group, Faculty Science and Technology, Universiti Sains Islam Malaysia, Nilai 71800, Malaysia.
Polymers (Basel) ; 15(6)2023 Mar 15.
Article en En | MEDLINE | ID: mdl-36987243
ABSTRACT
Three-dimensional printing is increasingly applied in dentistry to fabricate denture bases. Several 3D-printing technologies and materials are available to fabricate denture bases, but there is data scarcity on the effect of printability, mechanical, and biological properties of the 3D-printed denture base upon fabricating with different vat polymerization techniques. In this study, the NextDent denture base resin was printed with the stereolithography (SLA), digital light processing (DLP), and light-crystal display (LCD) technique and underwent the same post-processing procedure. The mechanical and biological properties of the denture bases were characterized in terms of flexural strength and modulus, fracture toughness, water sorption and solubility, and fungal adhesion. One-way ANOVA and Tukey's post hoc were used to statistically analyze the data. The results showed that the greatest flexural strength was exhibited by the SLA (150.8±7.93 MPa), followed by the DLP and LCD. Water sorption and solubility of the DLP are significantly higher than other groups (31.51±0.92 µgmm3) and 5.32±0.61 µgmm3, respectively. Subsequently, the most fungal adhesion was found in SLA (221.94±65.80 CFU/mL). This study confirmed that the NextDent denture base resin designed for DLP can be printed with different vat polymerization techniques. All of the tested groups met the ISO requirement aside from the water solubility, and the SLA exhibited the greatest mechanical strength.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Polymers (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Malasia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Polymers (Basel) Año: 2023 Tipo del documento: Article País de afiliación: Malasia