Vascular closure devices in living-donor nephrectomy: a much-needed systematic review and meta-analysis focusing on safety.
Burgos Revilla, Francisco Javier; Artiles Medina, Alberto; Domínguez Gutiérrez, Ana; Muriel García, Alfonso; Figueiredo, Arnaldo; Gómez Dos Santos, Victoria.
Afiliación
  • Burgos Revilla FJ; Department of Urology, Hospital Universitario Ramón y Cajal, Madrid, Spain.
  • Artiles Medina A; Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS), University of Alcalá, Madrid, Spain.
  • Domínguez Gutiérrez A; Board of the EAU Section of Transplantation Urology (ESTU), Coimbra, Portugal.
  • Muriel García A; Department of Urology, Hospital Universitario Ramón y Cajal, Madrid, Spain.
  • Figueiredo A; Instituto Ramón y Cajal de Investigación Sanitaria (IRYCIS), University of Alcalá, Madrid, Spain.
  • Gómez Dos Santos V; Department of Urology, Hospital Universitario Ramón y Cajal, Madrid, Spain.
BJU Int ; 132(3): 239-251, 2023 09.
Article en En | MEDLINE | ID: mdl-37017627
ABSTRACT

OBJECTIVE:

To assess the safety of vascular closure devices in living-donor nephrectomy (LDN), as staplers and non-transfixion techniques (polymer locking and metal clips) are the methods employed to secure the renal vessels during laparoscopic and robotic LDN, but the use of clips has come into question since the United States Food and Drug Administration and manufacturers issued a contraindication.

METHODS:

A systematic review and meta-analysis were conducted to assess the safety of vascular closure devices (International Prospective Register of Systematic Reviews [PROSPERO] registration CRD42022364349). The PubMed, Scopus, the Excerpta Medica dataBASE (EMBASE), and the Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS) databases were searched in September 2022. For comparative and non-comparative studies, incidence estimates and odds ratios (ORs), respectively, for the main variables regarding safety of vascular closure devices were pooled by using random effects meta-analyses. Quality assessment of the included comparative studies was conducted using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I) tool.

RESULTS:

Of the 863 articles obtained, data were retrieved from 44 studies, which included 42 902 patients. In non-comparative studies, the pooled estimate rates for device failure, severe haemorrhage rate, conversion to open surgery, and mortality were similar for both clips and staplers. Regarding the meta-analyses for comparative studies (three studies), there were no significant differences between the two groups for the severe haemorrhage rate (OR 0.57, 95% confidence interval [CI] 0.18-1.75; P = 0.33), conversion to open surgery (OR 0.35, 95% CI 0.08-1.54; P = 0.16), or death rate (OR 3.64, 95% CI 0.47-28.45; P = 0.22). Based on weak evidence, device failure was lower in the polymer clip group (OR 0.41, 95% CI 0.23-0.75; P = 0.00).

CONCLUSIONS:

This study has confirmed that there is no evidence for the superiority of any vascular closure device in terms of safety in LDN. Standardised recommendations for vascular control in this context should be carefully designed and prospectively evaluated.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Dispositivos de Cierre Vascular Tipo de estudio: Clinical_trials / Guideline / Systematic_reviews Límite: Humans País/Región como asunto: America do norte Idioma: En Revista: BJU Int Asunto de la revista: UROLOGIA Año: 2023 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Dispositivos de Cierre Vascular Tipo de estudio: Clinical_trials / Guideline / Systematic_reviews Límite: Humans País/Región como asunto: America do norte Idioma: En Revista: BJU Int Asunto de la revista: UROLOGIA Año: 2023 Tipo del documento: Article País de afiliación: España