Your browser doesn't support javascript.
loading
The relationship between maternal anemia and electronic fetal monitoring patterns.
Beermann, Shannon E; Watkins, Virginia Y; Frolova, Antonina I; Raghuraman, Nandini; Cahill, Alison G.
Afiliación
  • Beermann SE; Department of Obstetrics and Gynecology, Washington University School of Medicine in St. Louis, St. Louis, MO. Electronic address: beermann.s@wustl.edu.
  • Watkins VY; Department of Obstetrics and Gynecology, Duke University Health System, Durham, NC.
  • Frolova AI; Department of Obstetrics and Gynecology, Washington University School of Medicine in St. Louis, St. Louis, MO.
  • Raghuraman N; Department of Obstetrics and Gynecology, Washington University School of Medicine in St. Louis, St. Louis, MO.
  • Cahill AG; Department of Women's Health, Dell Medical School, The University of Texas at Austin, Austin, TX.
Am J Obstet Gynecol ; 229(4): 449.e1-449.e6, 2023 10.
Article en En | MEDLINE | ID: mdl-37086877
BACKGROUND: Anemia is a commonly diagnosed comorbidity in pregnancy that is associated with increased risk of maternal and neonatal complications. Recent data demonstrate that maternal anemia is associated with higher umbilical artery and umbilical vein O2 content at the time of delivery. OBJECTIVE: This study aimed to examine the relationship between maternal anemia and electronic fetal monitoring patterns associated with fetal hypoxia. STUDY DESIGN: This is a secondary analysis of a prospective cohort study of singleton term deliveries with cord gases and universal complete blood count collected on admission between 2010 and 2014. Maternal anemia was defined as hemoglobin ≤11.0 g/dL on admission. The primary outcome was a composite of high-risk category 2 electronic fetal monitoring features in the last 60 minutes before delivery (recurrent late and/or variable decelerations, minimal variability, tachycardia, or >1 prolonged deceleration); secondary outcomes were total deceleration area and total deceleration area >90th percentile. Of the 8580 patients in the original study, 8196 were included in the analysis. Outcomes were compared between patients with and without anemia. Multivariable logistic regression was used to adjust for potentially confounding factors, including hypertensive disorders of pregnancy and induction of labor. RESULTS: Of the 8196 patients with complete blood count on admission and fetal monitoring data, 2672 (32.6%; 2672/8196) were anemic and 5524 (67.4%; 5524/8196) were not. Patients with anemia were significantly less likely to have composite high-risk category 2 features on electronic fetal monitoring (34.2% vs 32.0%; adjusted risk ratio, 0.93; 95% confidence interval, 0.86-0.99). Women with anemia also had decreased total deceleration area and were less likely to have total deceleration area >90th percentile (18.7% vs 16.2%; adjusted risk ratio, 0.85; 95% confidence interval, 0.77-0.94). CONCLUSION: Patients with anemia are less likely to have high-risk category 2 electronic fetal monitoring features associated with fetal hypoxia. This finding is consistent with the association between maternal anemia and increased umbilical cord O2 content, and suggests that maternal anemia may be protective against intrapartum fetal hypoxia.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trabajo de Parto / Anemia Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Female / Humans / Newborn / Pregnancy Idioma: En Revista: Am J Obstet Gynecol Año: 2023 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Trabajo de Parto / Anemia Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Female / Humans / Newborn / Pregnancy Idioma: En Revista: Am J Obstet Gynecol Año: 2023 Tipo del documento: Article Pais de publicación: Estados Unidos