Your browser doesn't support javascript.
loading
Mechanical characterization of a novel biomimetic artificial disc for the cervical spine.
Jacobs, Celien A M; Kamali, S Amir; Abdelgawad, Abdelrahman M; Meij, Björn P; Ghazanfari, Samaneh; Tryfonidou, Marianna A; Jockenhoevel, Stefan; Ito, Keita.
Afiliación
  • Jacobs CAM; Orthopedic Biomechanics, Dept. of Biomedical Engineering, Eindhoven University of Technology, De Rondom 70, 5612, AP, Eindhoven, the Netherlands. Electronic address: c.a.m.jacobs@tue.nl.
  • Kamali SA; Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 108, 3584, CM, Utrecht, the Netherlands. Electronic address: s.a.kamali@uu.nl.
  • Abdelgawad AM; Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan, 226167, RD, Geleen, the Netherlands; Department of Biohybrid and Medical Textiles (BioTex), AME - Institute of Applied Medical Engineering, Helmho
  • Meij BP; Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 108, 3584, CM, Utrecht, the Netherlands. Electronic address: B.P.Meij@uu.nl.
  • Ghazanfari S; Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan, 226167, RD, Geleen, the Netherlands; Department of Biohybrid and Medical Textiles (BioTex), AME - Institute of Applied Medical Engineering, Helmho
  • Tryfonidou MA; Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 108, 3584, CM, Utrecht, the Netherlands. Electronic address: Tryfonidou@uu.nl.
  • Jockenhoevel S; Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan, 226167, RD, Geleen, the Netherlands; Department of Biohybrid and Medical Textiles (BioTex), AME - Institute of Applied Medical Engineering, Helmho
  • Ito K; Orthopedic Biomechanics, Dept. of Biomedical Engineering, Eindhoven University of Technology, De Rondom 70, 5612, AP, Eindhoven, the Netherlands. Electronic address: k.ito@tue.nl.
J Mech Behav Biomed Mater ; 142: 105808, 2023 06.
Article en En | MEDLINE | ID: mdl-37087956

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Anillo Fibroso / Disco Intervertebral Tipo de estudio: Prognostic_studies Idioma: En Revista: J Mech Behav Biomed Mater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2023 Tipo del documento: Article Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Anillo Fibroso / Disco Intervertebral Tipo de estudio: Prognostic_studies Idioma: En Revista: J Mech Behav Biomed Mater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2023 Tipo del documento: Article Pais de publicación: Países Bajos