Your browser doesn't support javascript.
loading
Clinical use of the canine foetal kidney formula in dogs of different maternal sizes during the last ten days before parturition.
Siena, Giulia; di Nardo, Francesca; Contiero, Barbara; Milani, Chiara.
Afiliación
  • Siena G; Department of Animal Medicine, Production and Health, University of Padova, Via dell'Università, 16, Legnaro, PD, 35020, Italy. giulia.siena@phd.unipd.it.
  • di Nardo F; Department of Animal Medicine, Production and Health, University of Padova, Via dell'Università, 16, Legnaro, PD, 35020, Italy.
  • Contiero B; Department of Animal Medicine, Production and Health, University of Padova, Via dell'Università, 16, Legnaro, PD, 35020, Italy.
  • Milani C; Department of Animal Medicine, Production and Health, University of Padova, Via dell'Università, 16, Legnaro, PD, 35020, Italy.
Vet Res Commun ; 47(3): 1653-1663, 2023 Sep.
Article en En | MEDLINE | ID: mdl-37095415
ABSTRACT
Data concerning the use of the canine foetal kidney length (L) formula in the prediction of parturition timing are still lacking. In our study, we aimed to evaluate the accuracy of the L formula in predicting the parturition date during the last 10 days of pregnancy. Twenty-five clinically healthy pregnant bitches, aged 2-9 years and weighing 3.5-52.2 kg, were ultrasonographically monitored from -11 to 0 days before parturition (dbp). Kidney L was measured for the three most caudal foetuses, and the parturition day was estimated using the kidney formula, whose accuracy was calculated as the percentage of cases estimated (ranges of ± 1 or ± 2 days) on the actual parturition date. A K-proportions test was performed to identify differences in the accuracy among maternal sizes and the sex ratio of pups, and a two-proportions z-test was performed to identify differences between litter size classes (≤ 7 vs. > 7 pups) and time ranges (-11/-5 and -4/0 dbp). An accuracy of 35% within ± 2 days was found in the range of -11/-5 dbp and an accuracy of 30% within ± 2 days was found in the range of -4/0 dbp. The accuracy differed between small (53% ±1 day and 60% ±2 days) and large (10% within ± 1 and ± 2 days) bitches (P = 0.019 within ± 1 day, and P = 0.007 within ± 2 days). For small litter sizes, the accuracy was 38% within ± 1 day and 44% within ± 2 days, and for large litter sizes, it was 14% within ± 1 and ± 2 days. A threshold value was found between litter size classes within ± 2 days. The use of the L formula during the last ten days of pregnancy did not seem to warrant good accuracy in the prediction of parturition date. Further studies on different maternal sizes should be performed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal / Parto Tipo de estudio: Diagnostic_studies Límite: Animals / Pregnancy Idioma: En Revista: Vet Res Commun Año: 2023 Tipo del documento: Article País de afiliación: Italia Pais de publicación: CH / SUIZA / SUÍÇA / SWITZERLAND

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Ultrasonografía Prenatal / Parto Tipo de estudio: Diagnostic_studies Límite: Animals / Pregnancy Idioma: En Revista: Vet Res Commun Año: 2023 Tipo del documento: Article País de afiliación: Italia Pais de publicación: CH / SUIZA / SUÍÇA / SWITZERLAND