The performance of metagenomic next-generation sequencing in diagnosing pulmonary infectious diseases using authentic clinical specimens: The Illumina platform versus the Beijing Genomics Institute platform.
Han, Shuangyu; Zhao, Zhan; Yang, Lei; Huang, Jie; Wang, Yubao; Feng, Jing.
Afiliación
  • Han S; Department of Respiratory and Critical Care Medicine, Tianjin Medical University General Hospital, Tianjin, China.
  • Zhao Z; Department of Respiratory and Critical Care Medicine, Tianjin Medical University General Hospital, Tianjin, China.
  • Yang L; Department of Respiratory and Critical Care Medicine, Tianjin Medical University General Hospital, Tianjin, China.
  • Huang J; Department of Respiratory and Critical Care Medicine, Tianjin Medical University General Hospital, Tianjin, China.
  • Wang Y; Department of Respiratory and Critical Care Medicine, Tianjin Medical University General Hospital, Tianjin, China.
  • Feng J; Department of Respiratory and Critical Care Medicine, Tianjin Medical University General Hospital, Tianjin, China.
Front Pharmacol ; 14: 1164633, 2023.
Article en En | MEDLINE | ID: mdl-37138853
ABSTRACT

Introduction:

Metagenomic next-generation sequencing (mNGS) has been increasingly used to detect infectious organisms and is rapidly moving from research to clinical laboratories. Presently, mNGS platforms mainly include those from Illumina and the Beijing Genomics Institute (BGI). Previous studies have reported that various sequencing platforms have similar sensitivity in detecting the reference panel that mimics clinical specimens. However, whether the Illumina and BGI platforms provide the same diagnostic performance using authentic clinical samples remains unclear.

Methods:

In this prospective study, we compared the performance of the Illumina and BGI platforms in detecting pulmonary pathogens. Forty-six patients with suspected pulmonary infection were enrolled in the final analysis. All patients received bronchoscopy, and the specimens collected were sent for mNGS on the two different sequencing platforms.

Results:

The diagnostic sensitivity of the Illumina and BGI platforms was notably higher than that of conventional examination (76.9% vs. 38.5%, p < 0.001; 82.1% vs. 38.5%, p < 0.001; respectively). The sensitivity and specificity for pulmonary infection diagnosis were not significantly different between the Illumina and BGI platforms. Furthermore, the pathogenic detection rate of the two platforms were not significantly different.

Conclusion:

The Illumina and BGI platforms exhibited similar diagnostic performance for pulmonary infectious diseases using clinical specimens, and both are superior to conventional examinations.