Your browser doesn't support javascript.
loading
Reliability of synthetic diffusion-weighted imaging with a high b-value for paediatric abdominal MRI.
Shin, H J; Son, N-H; Hwang, S H; Song, K.
Afiliación
  • Shin HJ; Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yongin Severance Hospital, Yonsei University College of Medicine, 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 16995, Republic of Korea. Electronic address: lamer-22@y
  • Son NH; Department of Statistics, Keimyung University, 1095 Dalgubeol-daero, Dalseo-gu, Daegu, 42601, Republic of Korea.
  • Hwang SH; Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yongin Severance Hospital, Yonsei University College of Medicine, 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 16995, Republic of Korea.
  • Song K; Department of Paediatrics, Division of Paediatric Endocrinology, Yonsei University College of Medicine, 363, Dongbaekjukjeon-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 16995, Republic of Korea.
Clin Radiol ; 78(8): 616-621, 2023 08.
Article en En | MEDLINE | ID: mdl-37149417
AIM: To evaluate the reliability of synthetic diffusion-weighted imaging (DWI) using a high b-value in comparison to conventional DWI for paediatric abdominal MRI. MATERIALS AND METHODS: Paediatric patients (<19 years old) who underwent liver or pancreatobiliary MRI with DWI using 10 b-values (b = 0, 25, 50, 75, 100, 200, 400, 600, 800, 1,500 s/mm2) from March to October 2021 were included in this retrospective study. Using the software, synthetic DWI using b = 1,500 s/mm2 was generated automatically by selecting the b-value required as output. Conventional and synthetic DWI values for b = 1,500 s/mm2 were measured at the liver, spleen, paraspinal muscle, and mass lesions, if present, and apparent diffusion coefficient (ADC) values were calculated using the mono-exponential model. Intraclass correlation coefficients (ICCs) were calculated to assess the reliability of conventional and synthetic DWI and ADC values with b = 1,500 s/mm2. RESULTS: Thirty paediatric patients (M:F = 22:8, mean 10.8 ± 3.1 years old) were included and four had tumours on abdominal MRI. ICC values were 0.906-0.995 between conventional and synthetic DWI and ADC with b = 1,500 s/mm2 in the liver, spleen and muscle. For mass lesions, ICC values were 0.997-0.999 for both synthetic DWI and ADC images. CONCLUSIONS: Synthetic DWI and ADC values obtained using a high b-value showed excellent agreement with conventional DWI for the liver, spleen, muscle, and mass in paediatric MRI.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen de Difusión por Resonancia Magnética / Neoplasias Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Child / Humans Idioma: En Revista: Clin Radiol Año: 2023 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen de Difusión por Resonancia Magnética / Neoplasias Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Child / Humans Idioma: En Revista: Clin Radiol Año: 2023 Tipo del documento: Article Pais de publicación: Reino Unido