The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report.
Panchal, Olivia; Schultz, Matthew J; Lutz, Rex W; Smith, Eric B; Deirmengian, Gregory K.
Afiliación
  • Panchal O; Orthopaedic Surgery, Texas College of Osteopathic Medicine, Fort Worth, USA.
  • Schultz MJ; Orthopeadic Surgery, Jefferson Health New Jersey, Stratford, USA.
  • Lutz RW; Orthopeadic Surgery, Jefferson Health New Jersey, Stratford, USA.
  • Smith EB; Orthopaedic Surgery, Rothman Orthopaedic Institute, Philadelphia, USA.
  • Deirmengian GK; Orthopaedic Surgery, Rothman Orthopaedic Institute, Philadelphia, USA.
Cureus ; 15(4): e37075, 2023 Apr.
Article en En | MEDLINE | ID: mdl-37153273

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Cureus Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos