Your browser doesn't support javascript.
loading
Opportunistic AI-enabled automated bone mineral density measurements in lung cancer screening and coronary calcium scoring CT scans are equivalent.
Naghavi, Morteza; De Oliveira, Isabel; Mao, Song Shou; Jaberzadeh, Amirhossein; Montoya, Juan; Zhang, Chenyu; Atlas, Kyle; Manubolu, Venkat; Montes, Marlon; Li, Dong; Atlas, Thomas; Reeves, Anthony; Henschke, Claudia; Yankelevitz, David; Budoff, Matthew.
Afiliación
  • Naghavi M; HeartLung AI Technologies, TMC Innovation, 2450 Holcomb Blvd, Houston, TX 77021.
  • De Oliveira I; HeartLung AI Technologies, TMC Innovation, 2450 Holcomb Blvd, Houston, TX 77021.
  • Mao SS; Lundquist Institute, Harbor UCLA Medical Center, 1124 W Carson St, Torrance, CA 90502, USA.
  • Jaberzadeh A; HeartLung AI Technologies, TMC Innovation, 2450 Holcomb Blvd, Houston, TX 77021.
  • Montoya J; HeartLung AI Technologies, TMC Innovation, 2450 Holcomb Blvd, Houston, TX 77021.
  • Zhang C; HeartLung AI Technologies, TMC Innovation, 2450 Holcomb Blvd, Houston, TX 77021.
  • Atlas K; HeartLung AI Technologies, TMC Innovation, 2450 Holcomb Blvd, Houston, TX 77021.
  • Manubolu V; Lundquist Institute, Harbor UCLA Medical Center, 1124 W Carson St, Torrance, CA 90502, USA.
  • Montes M; HeartLung AI Technologies, TMC Innovation, 2450 Holcomb Blvd, Houston, TX 77021.
  • Li D; Emory University, 201 Dowman Dr, Atlanta, GA 30322, USA.
  • Atlas T; HeartLung AI Technologies, TMC Innovation, 2450 Holcomb Blvd, Houston, TX 77021.
  • Reeves A; Cornell University, Ithaca, NY 14850, USA.
  • Henschke C; Mount Sinai, 1176 5th Ave, MC Level, New York, NY 10029, USA.
  • Yankelevitz D; Mount Sinai, 1176 5th Ave, MC Level, New York, NY 10029, USA.
  • Budoff M; Lundquist Institute, Harbor UCLA Medical Center, 1124 W Carson St, Torrance, CA 90502, USA.
Eur J Radiol Open ; 10: 100492, 2023.
Article en En | MEDLINE | ID: mdl-37214544
ABSTRACT
Rationale and

objectives:

We previously reported a novel manual method for measuring bone mineral density (BMD) in coronary artery calcium (CAC) scans and validated our method against Dual X-Ray Absorptiometry (DEXA). Furthermore, we have developed and validated an artificial intelligence (AI) based automated BMD (AutoBMD) measurement as an opportunistic add-on to CAC scans that recently received FDA approval. In this report, we present evidence of equivalency between AutoBMD measurements in cardiac vs lung CT scans. Materials and

methods:

AI models were trained using 132 cases with 7649 (3 mm) slices for CAC, and 37 cases with 21918 (0.5 mm) slices for lung scans. To validate AutoBMD against manual measurements, we used 6776 cases of BMD measured manually on CAC scans in the Multi-Ethnic Study of Atherosclerosis (MESA). We then used 165 additional cases from Harbor UCLA Lundquist Institute to compare AutoBMD in patients who underwent both cardiac and lung scans on the same day.

Results:

Mean±SD for age was 69 ± 9.4 years with 52.4% male. AutoBMD in lung and cardiac scans, and manual BMD in cardiac scans were 153.7 ± 43.9, 155.1 ± 44.4, and 163.6 ± 45.3 g/cm3, respectively (p = 0.09). Bland-Altman agreement analysis between AutoBMD lung and cardiac scans resulted in 1.37 g/cm3 mean differences. Pearson correlation coefficient between lung and cardiac AutoBMD was R2 = 0.95 (p < 0.0001).

Conclusion:

Opportunistic BMD measurement using AutoBMD in CAC and lung cancer screening scans is promising and yields similar results. No extra radiation plus the high prevalence of asymptomatic osteoporosis makes AutoBMD an ideal screening tool for osteopenia and osteoporosis in CT scans done for other reasons.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Idioma: En Revista: Eur J Radiol Open Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Idioma: En Revista: Eur J Radiol Open Año: 2023 Tipo del documento: Article
...