Your browser doesn't support javascript.
loading
Enhancing the sensitivity of rapid antigen detection test (RADT) of different SARS-CoV-2 variants and lineages using fluorescence-labeled antibodies and a fluorescent meter.
Nasrallah, Gheyath K; Ali, Fatma; Younes, Salma; Al Khatib, Heba A; Al-Thani, Asmaa A; Yassine, Hadi M.
Afiliación
  • Nasrallah GK; Biomedical Research Center, Qatar University, Doha, 2713, Qatar.
  • Ali F; Biomedical Sciences Department, College of Health Sciences, Qatar University, Doha, 2713, Qatar.
  • Younes S; Biomedical Research Center, Qatar University, Doha, 2713, Qatar.
  • Al Khatib HA; Biomedical Sciences Department, College of Health Sciences, Qatar University, Doha, 2713, Qatar.
  • Al-Thani AA; Biomedical Research Center, Qatar University, Doha, 2713, Qatar.
  • Yassine HM; Biomedical Sciences Department, College of Health Sciences, Qatar University, Doha, 2713, Qatar.
Heliyon ; 9(6): e17179, 2023 Jun.
Article en En | MEDLINE | ID: mdl-37325455
ABSTRACT
RT-qPCR is considered the gold standard for diagnosis of COVID-19; however, it is laborious, time-consuming, and expensive. RADTs have evolved recently as relatively inexpensive methods to address these shortcomings, but their performance for detecting different SARS-COV-2 variants remains limited. RADT test performance could be enhanced using different antibody labeling and signal detection techniques. Here, we aimed to evaluate the performance of two antigen RADTs for detecting different SARS-CoV-2 variants (i) the conventional colorimetric RADT (Ab-conjugated with gold beads); and (ii) the new Finecare™ RADT (Ab-coated fluorescent beads). Finecare™ is a meter used for the detection of a fluorescent signal. 187 frozen nasopharyngeal swabs collected in Universal transport (UTM) that are RT-qPCR positive for different SARS-CoV-2 variants were selected, including Alpha (n = 60), Delta (n = 59), and Omicron variants (n = 108). Sixty flu and 60 RSV-positive samples were included as negative controls (total sample number = 347). The conventional RADT showed sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 62.4% (95%CI 54-70), 100% (95%CI 97-100), 100% (95%CI 100-100), and 58% (95%CI 49-67), respectively. These measurements were enhanced using the Finecare™ RADT sensitivity, specificity, PPV, and NPV were 92.6% (95%CI 89.08-92.3), 96% (95%CI 96-99.61), 98% (95%CI 89-92.3), and 85% (95%CI 96-99.6) respectively. The sensitivity of both RADTs could be greatly underestimated because nasopharyngeal swab samples collected UTM and stored at -80 °C were used. Despite that, our results indicate that the Finecare™ RADT is appropriate for clinical laboratory and community-based surveillance due to its high sensitivity and specificity.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Heliyon Año: 2023 Tipo del documento: Article País de afiliación: Qatar

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Heliyon Año: 2023 Tipo del documento: Article País de afiliación: Qatar
...