Your browser doesn't support javascript.
loading
Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation.
Nagao, Shigeki; Yakushijin, Kimikazu; Higashime, Ako; Kawaguchi, Koji; Watanabe, Marika; Sakai, Rina; Ichikawa, Hiroya; Mizutani, Yu; Goto, Hideaki; Kakiuchi, Seiji; Kurata, Keiji; Kitao, Akihito; Miyata, Yoshiharu; Imamura, Yoshinori; Hirota, Yushi; Takahashi, Michiko; Kawamoto, Shinichiro; Yamamoto, Katsuya; Matsuoka, Hiroshi; Minami, Hironobu.
Afiliación
  • Nagao S; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Yakushijin K; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Higashime A; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Kawaguchi K; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Watanabe M; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Sakai R; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Ichikawa H; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Mizutani Y; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Goto H; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Kakiuchi S; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Kurata K; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Kitao A; Jerome Lipper Multiple Myeloma Center, Department of Medical Oncology, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA.
  • Miyata Y; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Imamura Y; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Hirota Y; BioResource Center, Kobe University Hospital, Kobe, Japan.
  • Takahashi M; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Kawamoto S; Diabetes and Endocrinology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Yamamoto K; Department of Nutrition, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Matsuoka H; Transfusion Medicine and Cell Therapy, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
  • Minami H; Division of Medical Oncology/Hematology, Department of Medicine, Kobe University Hospital and Graduate School of Medicine, Kobe, Japan.
Blood Cell Ther ; 6(2): 54-60, 2023 May 25.
Article en En | MEDLINE | ID: mdl-37342353
ABSTRACT
Hyperglycemia in the early days following allogeneic hematopoietic stem cell transplantation (allo-HSCT) is a well-known risk factor for acute graft-versus-host disease (GVHD) and non-relapse mortality. The FreeStyle Libre Pro, a factory calibrated continuous glucose monitoring (CGM) device, has been used for the retrospective analysis of glucose testing in patients with diabetes. We assessed the safety and accuracy of the device in patients undergoing allo-HSCT. We recruited eight patients who underwent allo-HSCT between August 2017 and March 2020. They wore the FreeStyle Libre Pro on the day before or on the day of transplantation until 28 days after transplantation. Adverse events, especially bleeding and infection, were monitored to assess safety, and blood glucose levels were measured and compared with the device values. None of the eight participants experienced bleeding that was difficult to stop from the sensor site or local infection that required antimicrobial administration. The device value was well correlated with blood glucose (correlation coefficient r=0.795, P<0.01); however, the overall mean absolute relative difference was 32.1%±16.0%. Our study demonstrated the safety of FreeStyle Libre Pro in allo-HSCT patients. However, the sensor results tended to be lower than the blood glucose levels.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Risk_factors_studies Idioma: En Revista: Blood Cell Ther Año: 2023 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Risk_factors_studies Idioma: En Revista: Blood Cell Ther Año: 2023 Tipo del documento: Article País de afiliación: Japón